NAPCO Gemini GEM-P1632 Installation Instructions Manual page 31

Control panel/communicator
Table of Contents

Advertisement

WI808F 8/03
!
Zone Number on Pulse Alarm. If selected, an Alarm Code need not be programmed (the zone number will replace the Alarm Code), however
codes for restore, trouble, etc. are still required. Thus, in the foregoing example, if "E" is the designated Restore Code, and Zone 24 trips and is
restored, the communicator will send "1234 24" (Account No. 1234; Alarm, Zone 24) followed by "1234 E4" (Account No. 1234; Zone 24 Restored).
!
Single-Digit (Pulse Only) Format. The single digit sent for a particular digit of the zone number.
!
Sum-Check Format. Sum Check is a sophisticated data format used to enhance the speed and check the accuracy of the received transmission.
This format should be preferred whenever the central station is capable of receiving it. After transmitting the Subscriber Identification Number and the
Alarm Code, the communicator sends a verifying digit that is the sum of both. The receiver compares the verifying digit with the sum of the other
numbers to check transmission accuracy. This feature eleiminates the need to repeat data and saves time.
!
3/1 with Extended Restores. Some receivers require a three-digit Account Code followed by a single-digit Alarm Code. Example. In another
installation, the Alarm Subscriber Number is "123"; an alarm on Zone 1 is restored. The Restore Code for Zone 1 is "E,1". The communicator will send
"123 E" (Account No. 123 Restored); followed by "EEE 1" (Restored, Zone 1).
!
Modem Formats. Modem formats (SIA, Point ID) are preset and automatic but require a Type for each zone. Program Zone Type as follows:
Fire* = "1"; Panic = "2"; Burglary = "3"; Holdup = "4"; Gas Alarm = "7"; Heat Alarm = "8"; Auxiliary Alarm = "A" (Keypad displays "0"); 24-Hour Aux.
Alarm = "B".
!
Pager Formats. The control panel has provisions for dialing a pager phone number. The panel will wait for ringing, wait for silence, then send its
data. Caution: Because there is no handshake/kissoff, this feature should only be used for Double Reporting; it may not be used for Backup
Reporting. Only one report is sent for any call. Pager digits are limited to "0" through "9". Digits represented by "A" through "F" will be converted to "0"s
for transmission purposes. Pager formats are 10 digits, arranged as illustrated by the following examples.
Alarms, restores, etc. are transmitted in a 3-2-4 arrangement representing Report Code, Descriptor and Account Number.
Example 1. Burglary, Zone 22 (Report Code = "3".)
Transmits: 003 22 1234, where
003 = Report Code (always two zeros + programmable Report-Code digit, 0–9);
22 = Descriptor (2-digit descriptor, zone number: 01–32);
1234 = Account Number (4 digits, programmable).
Openings, closings, etc. are transmitted in a similar arrangement
Example 2. Closing, User 12 (Closing Code = "8")
Transmits 008 12 1234, where
008 = Report Code (always two zeros + programmable Opening/Closing digit, 0–9)
12 = Descriptor (2-digit descriptor (user number: 01–32);
1234 = Account Number (4 digits, programmable).
Keypad Report Codes and System Report Codes are transmitted in the same format.
Compatible Receivers. The following receivers are compatible with the GEM-P1632:
!
FBI CP220. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; SIA; Radionics Slow; Radionics Fast; Universal
High Speed.
!
Ademco 685. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; Radionics Slow; Radionics Fast; Universal High
Speed; Ademco Point ID.
!
Radionics 6500. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; Radionics Slow; Radionics Fast; Universal
High Speed.
!
Osborne-Hoffman Quickalert. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; SIA; Radionics Slow; Universal
High Speed; Ademco Point ID.
!
Silent Knight 9000. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; Radionics Slow; Radionics Fast; Universal
High Speed; SIA.
Date/Time
A Date/Time can be set in the Keypad Dealer Program Mode or Quickloader program. "Enable Set Date/Time Message" will
automatically request the date and time at the keypad after power failures.
Day Zone(Open; Short); Alarm on Day Zone; Disable Auto-Reset on Day Zone; Reset Day Zone with Arm/Disarm Only
A Day Zone will give an audible and visual indication at the keypad if there is a problem on the loop while disarmed. Open- and short-
circuit conditions are programmed separately, by zone. This feature may be used to warn of a problem (a break in a window foil, for
example) during the day, when the panel is not normally armed. When the Day Zone is tripped, "
(s) will alternately display at the keypad and the sounder will pulse. Press the
keypad. "
ZONE FAULT
" will be displayed until the condition is corrected. If Reset Day Zone With Arm/Disarm Only is programmed, reset
the Day-Zone indication at the keypad. A User Code is required to reset the keypad display. If Alarm on Day Zone is programmed for
a zone, a Day Zone condition will cause the alarm outputs programmed for that zone (sirens, relays) to activate.
Note: (1) If a zone is programmed for both "Day Zone Open" and "Day Zone Short", either condition must be reset before the other can
activate. (2) Day Zone Short will not function if No EOL Resistor is also programmed.
Report Trouble or Trouble Restore is programmed in conjunction with Day Zone Open/Day Zone Short and Trouble on Open/Trouble
on Short (the trouble reported will be that programmed under Day Zone Open and/or Day Zone Short).
Note: Do not program a Day Zone for 24-hour protection. The keypad will annunciate as a Day Zone but the panel will transmit an
Alarm Code and a Trouble Code when tripped.
L
NAPCO Security Systems
DAY ZONE TRBL
button to silence the sounder and reset the
C
X
GEM-P1632 Installation Instructions
!
Page 31
" and the zone number