Diagnostic Menus; Menus Field; Clear Cntrs Field; Pr Field (Dsr-6402, Dsr-6403, And Dsr-6404 Only) - Motorola DSR-6403 Operator's Manual

Dsr-6400 series satellite multiplex receiver/transcoder
Table of Contents

Advertisement

Diagnostic Menus

Use the unit's diagnostic menu to acquire information for troubleshooting purposes. The menus
also provide test waveforms and use other diagnostic information displayed on an NTSC
television monitor connected through the back panel's Video and OSD Video port. Press the 
buttons until the DIAGNOSTIC menu appears.

Menus Field

Use the Menus field to enable or disable the on-screen diagnostics. Press the 4 button until the
cursor is at the MENUS label, and press ENTER to move into the field. Press the  buttons to
scroll to the desired screen. Press ENTER to confirm the selection and exit the field.
Notice that if the Menus field is set to any option other than Off, Diag F, or Diag G; the Clear Cntrs
(Clear Counters) field also appears.
Use the  buttons to choose the desired option (Fast Facts 1 through 5 or Diag A through Diag G)
and press ENTER to confirm the selection and exit the field. For more information about Fast Facts
screens, see "Diagnostics" on page 85.

Clear Cntrs Field

Use this field to reset selected counters to zero. This field is primarily for use with hotline troubleshoot-
ing, and it is recommended that it be used only when so directed and does not affect the unit's opera-
tion, but it may give misleading troubleshooting results. To clear counters, press the 4 button until the
cursor is at the Clear Cntrs label, and press ENTER to move into the field. Press the  button to select
Yes and press ENTER to reset the counters to zero and return the field to No.

PR Field (DSR-6402, DSR-6403, and DSR-6404 only)

The PR (processor) field does not appear on a DSR-6401. Press the 4 button until the cursor is at
the PR label, and press ENTER to move into the field. While ensuring that the cursor remains on
the up/down symbol ( ), press the  buttons to scroll throughout the available processor
values. Press ENTER to confirm the selection and exit the field.
Note: Changing this value will change all other PR fields throughout this unit's menu system to
the same value that is set here.
DSR-6400 Series
DIAG
Menus
E
Off
DIAG
Menus
Clear Cntrs
E
Fact 1
No
 
PR
1
Default: Off
PR
1
Default: 1
75