To manually activate an available code version (either revert or upgrade)
Important: Use caution when executing the Available option. Once the Available option is
selected and ENTER is pressed, the unit will make the specified code version as the current
active version and will then perform an automatic reboot.
Press the buttons to specify the Available option.
1.
Press the ENTER button.
2.
When the warning message appears, press ENTER to activate the specified
3.
code version.
Or, if it is necessary to abort this process, press any arrow button ( 4 ) to back out
of the field and leave the unit unchanged.
Important: If the unit is being reverted to an older code version, the ----- selection (five
dashes) will now replace the Available option within the menu system, and more importantly,
the unit cannot return to the former code version. At this point, the only way to activate
another code version is to wait for the next code download broadcast.
Core Menu
Press the buttons until the Core menu appears. Use this menu to change the LCD contrast.
Contrast Field
To adjust the front-panel LCD contrast, press the 4 button until the cursor is at the Contrast label,
and press ENTER to move into the field. Use the arrow buttons ( ) to select a value between 0
and 30, with 0 representing the least contrast and 30 the most contrast. Adjust the contrast so that the
LCD panel can be read clearly. Press ENTER to confirm the selection and exit the field.
Video Out Menu
Press the buttons until the VIDEO OUT menu appears. Use this menu to modify the video
output format. When the input to the uplink encoder is 525-line, the 525 field selects the unit analog
video output, either NTSC or PAL-M. When the input to the uplink encoder is 625-line, the 625
field selects the unit analog video output, either PAL 625 or PAL-N.
DSR-6400 Series
CORE
Contrast
E
18
Default: 18
VIDEO OUT 525
625
E
NTSC
PAL-625
47