Daikin FTXN09KEVJU Operation Manual page 8

K series split-system room air conditioners
Hide thumbs Also See for FTXN09KEVJU:
Table of Contents

Advertisement

EDUS041111_a
Indoor Unit
Model
60 Hz,
208 - 230V
Outdoor Unit
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min.~Max.)
Power Factor
EER (Rated) (Max.~Min.)
Energy Efficiency
SEER
Liquid
Gas
Piping Connections
Indoor Unit
Drain
Outdoor Unit
Heat Insulation
Max. Interunit Piping Length
Min. Interunit Piping Length
Max. Interunit Height Difference
Chargeless
Amount of Additional Charge of Refrigerant
Indoor Unit
Front Panel Color
H
M
Airflow Rate
L
SL
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation Sound
H / M / L / SL
Sound Power
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant Oil
Charge
Type
Refrigerant
Charge
Airflow Rate
H
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight
Gross Weight
Operation Sound
H
Sound Power
H
Drawing No.
Note:
 The data are based on the conditions shown in the table below.
Cooling
Indoor ; 80°FDB(27°CDB), 67°FWB(19.4°CWB)
Outdoor ; 95°FDB(35°CDB / 75°FWB(24°CWB)
Room Air Conditioners K-Series
FTXN15KVJU
RKN15KEVJU
kW
4.4 (1.7 ~ 4.4)
Btu/h
15,000 (5,800 ~ 15,000)
kcal/h
3,780 (1,460 ~ 3,780)
L/h
A
W
1,250 (280 ~ 1,250)
%
Btu/h·W
in. (mm)
 1/2 (12.7)
in. (mm)
I.D. 9/16 (14.3), O.D. 11/16 (17.5)
in. (mm)
I.D. 11/16 (17.5) (Hole)
Both Liquid and Gas Pipes
ft. (m)
ft. (m)
ft. (m)
ft. (m)
oz/ft (g/m)
FTXN15KVJU
cfm
(m³/min)
Cross Flow Fan
W
Steps
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
A
W
%
Microcomputer Control
in. (mm)
11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
in. (mm)
13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
Lbs (kg)
Lbs (kg)
dB(A)
45 / 41 / 36 / 33
dB(A)
RKN15KEVJU
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
W
oz (kg)
Lbs (kg)
cfm
1,472 (41.7)
(m³/min)
W
A
W
1,216 - 1,216
%
A
in. (mm)
23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
in. (mm)
25-3/4 × 37-1/8 × 15-3/4 (654 x 943 x 400)
Lbs (kg)
Lbs (kg)
dB(A)
dB(A)
3D071519D
Piping Length
25 ft (7.5)
2.9
6.11 - 5.53
98.4 - 98.3
12.0
18.0
1/4 (6.4)
98.4 (30)
4.9 (1.5)
65.6 (20)
32.8 (10)
0.21 (6.0)
White
14.7 (519)
438 (12.4)
364 (10.3)
335 (9.5)
43
0.17 - 0.15
34 - 34
96.2 - 98.6
26.5 (12)
38.0 (17)
61
1,100
FVC50K
22.1 (0.63)
R-410A
3.2 (1.5)
Propeller
60
5.94 - 5.38
98.4 - 98.3
6.11
93 (42)
100 (45.4)
51
65
Specifications
FTXN18KVJU
RKN18KEVJU
5.28 (1.7 ~ 5.28)
18,000 (5,800 ~ 18,000)
4,540 (1,460 ~ 4,540)
3.9
7.33 - 6.63
1,500 (300 ~ 1,500)
98.4 - 98.4
12.0
18.0
1/4 (6.4)
 1/2 (12.7)
I.D. 9/16, O.D. 11/16 (17.5)
I.D. 11/16 (17.5) (Hole)
Both Liquid and Gas Pipes
98.4 (30)
4.9 (1.5)
65.6 (20)
32.8 (10)
0.21 (6.0)
FTXN18KVJU
White
16.2 (572)
480 (13.6)
403 (11.4)
360 (10.2)
Cross Flow Fan
43
5 Steps, Quiet, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.17 - 0.15
34 - 34
96.2 - 98.6
Microcomputer Control
11-7/16 × 41-5/16 × 9-3/8 (291 x 1049 x 238)
13-5/16 × 45-3/16 × 14-7/16 (338 x 1148 x 367)
26.5 (12)
38.0 (17)
45 / 41 / 36 / 33
61
RKN18KEVJU
Ivory White
Hermetically Sealed Swing Type
2YC36BXD
1,100
FVC50K
22.1 (0.63)
R-410A
3.2 (1.5)
1,667 (47.2)
Propeller
60
7.16 - 6.48
1,466 - 1,466
98.4 - 98.4
7.33
23-7/16 × 31-5/16 × 11-13/16 (595 x 795 x 300)
25-3/4 × 37-1/8 × 15-3/4 (654 x 943 x 400)
93 (42)
100 (45.4)
53
67
3D071520C
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents