Daikin FTXN09KEVJU Operation Manual page 34

K series split-system room air conditioners
Hide thumbs Also See for FTXN09KEVJU:
Table of Contents

Advertisement

EDUS041111_a
Symbols:
AFR
: Airflow rate
BF
: Bypass factor
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
SHC
: Sensible heat capacity
PI
: Power input
Room Air Conditioners K-Series
Note:
(m
/min.)
1. Ratings shown are net capacities which include a deduction for indoor fan
3
motor heat.
2.
3. TC, PI and SHC must be calculated by interpolation using the figures in
(°C) / (°F)
the tables. (Figures out of the tables should not be used for calculation.)
(°C) / (°F)
4. About SHC which are not mentioned on the table, please calculate them
with around values in direct proportion.
(kW) / (kBtu/h)
5. Capacities are based on the following conditions.
(kW) / (kBtu/h)
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
(kW)
6. Cooling capacity at
3D071295
shows nominal (rated) capacities and power input.
15°CDB and 5°FDB.
Temp: Celsius
TC, SHC, PI: kW
INDOOR
OUTDOOR
EWB
EDB
–15 (°CDB)
°C
°C
TC
SHC
PI
14.0
20.0
4.84
3.70
0.59
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR
OUTDOOR
EWB
EDB
5 (°FDB)
°F
°F
TC
SHC
PI
57.2
68.0
16.52
12.63
0.59
Capacity Tables
33