Capacity Tables
FTXN12KEVJU + RXN12KEVJU (60 Hz, 208 / 230 V)
Cooling
AFR
9.3
BF
0.24
Temp: Celsius
TC, SHC, PI: kW
INDOOR
EWB
EDB
20.0
°C
°C
TC
SHC
14.0
20.0
2.33
1.86
16.0
22.0
3.11
2.14
18.0
25.0
3.93
2.56
19.4
26.7
4.01
2.67
22.0
30.0
4.25
2.56
24.0
32.0
4.42
2.49
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR
EWB
EDB
68.0
°F
°F
TC
SHC
57.2
68.0
7.94
5.44
60.8
71.6
10.62
7.44
64.4
77.0
13.40
9.95
67.0
80.0
13.68
10.04
71.6
86.0
14.51
9.75
75.2
89.6
15.06
9.47
Heating
AFR
10.1
Temp: Celsius
TC, PI: kW
INDOOR
EDB
–15.0
°C
TC
PI
15.0
1.89
0.79
21.1
1.77
0.81
22.0
1.72
0.82
24.0
1.68
0.82
25.0
1.65
0.83
27.0
1.61
0.84
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR
EDB
5.0
°F
TC
PI
59.0
6.43
0.79
70.0
6.03
0.81
71.6
5.87
0.82
75.2
5.72
0.82
77.0
5.64
0.83
80.6
5.48
0.84
26
25.0
PI
TC
SHC
PI
TC
0.89
2.33
1.86
1.02
2.33
0.92
3.11
2.14
1.02
3.11
0.94
3.77
2.48
1.03
3.60
0.94
3.85
2.59
1.03
3.68
0.95
4.09
2.50
1.04
3.93
0.96
4.25
2.43
1.04
4.09
77.0
PI
TC
SHC
PI
TC
0.66
7.94
5.44
0.76
7.94
0.81
10.62
7.44
0.92
10.62
0.94
12.84
9.31
1.03
12.28
0.94
13.12
9.41
1.03
12.56
0.95
13.95
9.16
1.04
13.39
0.96
14.50
8.90
1.04
13.94
OUTDOOR TEMPERATURE (°CWB)
–10.0
–5.0
TC
PI
TC
PI
TC
2.27
0.83
2.65
0.87
3.56
2.15
0.85
2.53
0.89
3.42
2.10
0.86
2.48
0.90
3.37
2.06
0.86
2.44
0.91
3.31
2.03
0.87
2.41
0.91
3.29
1.99
0.88
2.37
0.92
3.23
OUTDOOR TEMPERATURE (°FWB)
14.0
23.0
TC
PI
TC
PI
TC
7.72
0.83
9.02
0.87
12.14
7.33
0.85
8.62
0.89
11.67
7.17
0.86
8.47
0.90
11.48
7.01
0.86
8.31
0.91
11.30
6.93
0.87
8.23
0.91
11.20
6.77
0.88
8.07
0.92
11.02
OUTDOOR TEMPERATURE (°CDB)
30.0
32.0
SHC
PI
TC
SHC
1.86
1.11
2.33
1.86
2.14
1.11
3.11
2.14
2.40
1.12
3.54
2.37
2.52
1.12
3.62
2.49
2.43
1.13
3.86
2.41
2.37
1.13
4.02
2.34
OUTDOOR TEMPERATURE (°FDB)
86.0
90.0
SHC
PI
TC
SHC
5.44
0.87
7.94
5.44
7.44
1.04
10.62
7.44
8.70
1.12
12.06
8.47
8.81
1.12
12.34
8.58
8.59
1.13
13.16
8.37
8.36
1.13
13.72
8.16
0
6.0
10.0
PI
TC
PI
TC
1.13
4.10
1.19
4.45
1.16
3.96
1.22
4.32
1.17
3.91
1.23
4.26
1.18
3.85
1.24
4.21
1.19
3.82
1.25
4.17
1.20
3.77
1.26
3.85
32.0
43.0
50.0
PI
TC
PI
TC
1.13
13.97
1.19
15.19
1.16
13.50
1.22
14.72
1.17
13.31
1.23
14.53
1.18
13.13
1.24
14.35
1.19
13.03
1.25
14.22
1.20
12.85
1.26
13.13
35.0
PI
TC
SHC
PI
TC
1.14
2.33
1.86
1.20
2.33
1.15
3.11
2.14
1.20
3.11
1.15
3.44
2.33
1.21
3.28
1.16
3.52
2.45
1.21
3.36
1.16
3.76
2.37
1.22
3.60
1.17
3.93
2.31
1.22
3.76
95.0
PI
TC
SHC
PI
TC
0.91
7.94
5.44
0.98
7.94
1.09
10.62
7.44
1.16
10.61
1.15
11.72
8.13
1.21
11.16
1.16
12.00
8.24
1.21
11.44
1.16
12.83
8.05
1.22
12.27
1.17
13.38
7.85
1.22
12.82
PI
1.23
1.26
1.27
1.28
1.29
1.29
PI
1.23
1.26
1.27
1.28
1.29
1.23
Room Air Conditioners K-Series
EDUS041111_a
40.0
SHC
PI
1.86
1.29
2.14
1.29
2.25
1.30
2.38
1.30
2.31
1.31
2.25
1.31
104.0
SHC
PI
5.44
1.03
7.43
1.21
7.58
1.22
7.70
1.22
7.54
1.23
7.37
1.23