Download Print this page

ProForm Crosswalk 831297311 Owner's Manual page 6

Advertisement

OPERATION
AND ADJUSTMENT
APPLYINGSIUCONE LUBRICANT
has a grounding plug as shown in Drawing 1 below.
To reduce the frictionof the walking belt and minimize
wear, a non-oil, non-petroleum-bosesiliconelubricant
must be applied to the walking platform before the
CROSS WALK is used. WITH THE POWER CORD
UNPLUGGED,lift each side of thewalking belt and
spray lubricantgenerouslyonto the area shaded in the
drawing below. Reapply lubricant after every ten hours
of use, or whenever performancedecreases. Lubricantis
available at hardware and automotive stores.
Uni°Sport
TM
spray is recommended.
Grounded Outlet Box
Grounding Plug
Grounding Pin
Grounded Outlet
Silicone
Apply silicone to the
entire shaded area.
PLUGGING IN THE POWER CORD
Thisproduct must be grounded. If it shouldmalfunction
or break down, grounding provides a path of least resis-
tance for electriccurrent to reducethe risk of electric
shock.Thisproduct is equipped with a cord having an
equipment-grounding conductor and a grounding plug.
Plug the power card into an appropriate outlet Ihat is
properly installed and grounded in accordance with all
local codesand ordinances.
4k DANGER:
Improper connectionof the
equlpment-grounding conductor can resultin a risk of
electricshock.Check with a qualified electricianor ser-
viceman if you are in doubt as to whether the productis
properly grounded. Do not modify the plug provided
with the product--if it will not fit the outlet, have a prop-
er outletinstalledby a qualified electrician.
Thisproduct is for use on a nominal 120-vott circuit, and
A temporary adapter like the adapter shownin Drawing
2 may be used to connect this plug to a 2-pole recepta-
cle as shown in Drawing 2 if a properly grounded outlet
isnot available.
Grounded Outlet Box
Adapter
Grounding Pin
Grounding Plug
Lug
'_
Metal Screw /
The temporary adapter shouldbe used only until a prop-
erly grounded outlet (Drawing 1) can be installedby a
qualified electrician. The green-colored ear, lug, or the
like extending from the adapter must be connected to a
permanent ground suchas a properly grounded outlet
box cover. Whenever the adapter is used, it mustbe
held in place by a metal screw.
Some 2-pole receptacle outlet box covers are not
grounded. Contact a qualified electrician to determine
if the outlet box cover is grounded before using an
adapter.
6