C.
If the walking belt is overtightened, performance may be reduced
and the walking belt permanently damaged. UNPLUG THE POWER
CORD. Using the allen wrench included, turn both rear roller adjust-
ment bolts counterclockwise 1/4_ of a turn. When the tension of the
walking belt is correct, you should be able to lift each side of the
walking belt 2-3 inches; the center of the walking belt should just
touch the surface of the walking platform. Be sure to keep the walk-
ing belt centered. Run the treadmill for a few minutes. Repeat until
the tensionof the walking belt is cprrect. Note: Store the allen
wrench in the handy wrench clip.
6. SYMPTOM: THE WALKING BELTIS OFF-CENTER OR SUPS
_"-3"
Rear Roller
_..__en_,_lts
Wrench Clip _
_----_-_)/
a. If the walking belt has shiftedto the left, first remove the safety key
r
°and UNPLUG THE POWER CORD. Using the allen wrench, turn the
left rear roller adjustment bolt clockwise, and the right bolt counter-
clockwise, 1/4 of a turn each. Be careful not to overtighten the
walking belt. Plug in the power cord, insertthe safety key and run
the treadmill for a few minutes. Repeat until the belt is centered.
b.ff the walking belt has shifted to the right, first remove the safety
key and UNPLUG THE POWER CORD. Using the allen wrench, turn
the left rear roller adjustment bolt counterclockwise, and the right
bolt clockwise, 1/4 of a turn each. Be careful not to overtighten the
_i _lking
belt. Plug in the power cord, insert the safety key and run
_
the treadmill for a few minutes. Repeat until the belt is centered.
c. If the walking belt slipswhen walked on, first remove the safety key
.... and UNPLUG THE POWER CORD. Using the allen wrench, turn both
_ i rear roller adjustment bolts clockwise, 1/4 of a turn. When the
walking belt is correctly tightened, you should be able to lift each
side of the walking belt 2-3 inches off the walking platform. The
center of the walking belt should just touch the walking platform. Be
careful to keep the walking belt centered. Plug in the power cord,
in_rt the safety key and run the treadmill for a few minutes. Repeat
until the walking belt is properly tightened.
7. SYMPTOM: IT IS DIFFICULTTO INSERTOR REMOVE THE LOCK PIN
a. If it is difficultto insertthe lock pin, do not hit the end of the lock pin; twisteach upper body arm slightlyin order
to align the holes. Do not twistthe upper body arms too for or the treadmill may be damaged.
STORAGE
Before converting the CROSS WALK to the stowaway position, turn the resistancecontrol (see the drawing on page
8) counterclockwiseuntil the control turns freely. Next, unplug the power cord. Remove the lock knob and washer
from the upright and lay the upright and the upper body arms on the walking belt. Keep the lock knob and washer in a
securelocation.