Summary of Audible/Visual Notifications

Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
SOUND
CAUSE
LOUD,
FIRE ALARM or CO ALARM
INTERRUPTED *
(CO: keypad/detector only; not
external sounder)
Keypad & Ext.
LOUD,
BURGLARY/AUDIBLE
CONTINUOUS *
EMERGENCY ALARM
Keypad & Ext.
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING ATTEMPT
Keypad only
c. BYPASS VERIFY
ONE SHORT BEEP
a. SYSTEM IS IN TEST MODE
(once every 30 secs)
b. LOW BATTERY AT A
Keypad only
c. SYSTEM WILL AUTOARM
TWO SHORT BEEPS
ARM AWAY or MAXIMUM
Keypad only
THREE SHORT
a. ARM STAY, NIGHT-STAY,
BEEPS
Keypad only
b. ZONE OPENED WITH
RAPID BEEPING
a. TROUBLE
Keypad only
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
e. LAST 10 SEC of EXIT DELAY
SLOW BEEPING
a. EXIT DELAY WARNING
Keypad only
b. ENTRY DELAY WARNING
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 46 –
Fixed-Word Display Keypads
WITH AN OPEN ZONE.
TRANSMITTER
WITHIN 10 MINUTES
OR INSTANT
SYSTEM IN CHIME MODE.
DISPLAY
FIRE or ALARM (for CO) is displayed; zone
number of zone in alarm is displayed. If a fire
alarm is manually activated, zone number 95
will be displayed.
ALARM is displayed. Zone number of zone in
alarm is also displayed.
a. READY indicator light comes on.
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
c. No special display.
AWAY is displayed. Red ARMED indicator is
lit.
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the [∗]
key is pressed.
a. CHECK displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone number
of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70 is displayed.
e. No special display.
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.