This addendum applies to systems with control panel microprocessor version 4.0 or higher.
SUMMARY OF PLATFORM UPDATE FEATURES
The following features are new to this control panel.
Feature
Data field ∗29 Long Range Radio Enable is
now a Menu mode.
Data field ∗91 Option Selection now has
bell supervision option.
Zone Type 14 Carbon Monoxide has a
change in behavior.
∗ ∗ ∗ ∗ 91
Option Selection
0 = None
1 = Bell Supervision Processing†
4 = AAV
8 = Exit Delay Restart/Reset ††
#+12 = AAV and Exit Delay Restart/Reset
SIA-Compliant Controls:
Options: Same as for VISTA-10P.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70) entered in
field *40; (when selected, the system dials
the entry in field *40 only on alternate dial
attempts; this allows proper dialing in the
event call waiting service is later canceled by
the user).
∗ ∗ ∗ ∗ 29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming)
This mode is for programming an IP, GSM, or IP/GSM Communicator Module using an alpha keypad. Alternatively, these options can be
programmed via the AlarmNet Direct website. After programming is complete, the module must be registered with AlarmNet before reporting via the
communication device can occur. Refer to the device's instructions for registration procedures.
NOTE: The module must be set to device address 3.
IMPORTANT: The use of an IP/GSM Communicator Module requires an
AlarmNet–I account. Please obtain the account information from the central
station prior to programming this module.
Using an Alpha Keypad as a 7720P Programming Tool
When programming with ∗29 menu mode, the alpha keypad mimics the functions of
the 7720P Programming Tool. See figure to right and table below for 7720P key
functions. Each key has two possible functions: a normal function and a SHIFT
function.
Normal functions: The numeric values labeled directly on the keys and the left-
hand functions shown in diagram on the ABC keys. To perform a normal key
function, simply press the desired key.
SHIFT functions: Those functions shown in diagram above the numerical keys
and the right-hand functions shown on the ABC keys. To perform a SHIFT key
function, press SHIFT key (D key), then press the desired function key (shift
function is indicated by the lit READY LED).
INSTALLATION SUPPLEMENT
for VISTA-10P Security System
NEW PLATFORM UPDATE FEATURES
Description
∗29 Long Range Radio Enable is now a menu mode for programming a connected communication
device (7845GSM, 7845i-GSM) using the keypad rather than needing a 7720P Programming Tool.
This feature is also known as Pass-Through Programming Mode.
∗91 Option Selection has new option "1" for Bell Supervision (1 = enable; 0 = disable).
If bell supervision is enabled, you must also cut the red PCB Bell Supervision jumper.
Zone Type 14 Carbon Monoxide sounds only at the keypad and no longer affects the bell output.
NOTE: when used with an output function, the carbon monoxide zone type activates upon CO alarms
only. Does not activate for trouble conditions.
Options
Options: Select the desired options by adding the values of each desired option.
IMPORTANT: AAV should not be used when Paging or Alarm Reports are sent to a
secondary number unless the monitoring zone option is used (which pauses calls).
Otherwise, the call to the secondary number by the communicator after the alarm
report will prevent the AAV from taking control of the telephone line, and the AAV
"Listen in" session cannot take place.
UL: must use ADEMCO UVCM module; Exit Delay Restart/Reset must be disabled
UL: If Sounder Delay used, entry delay (*35) must be 30 sec. max.
SIA Guidelines: Exit Delay should be enabled.
If bell supervision selected, you must also cut the red PCB Bell Supervision jumper.
††
"Exit Delay Restart/reset" option allows use of the [∗] key to restart the exit delay at any time
when the system is armed STAY or INSTANT. This feature also enables automatic exit delay reset,
which resets exit delay if the entry/exit door is re-opened and closed before exit delay time expires
after arming AWAY. Automatic Exit Delay Reset occurs only once during an armed AWAY period.
[8, 0]
SIA-Compliant Controls:
Call Wait Disable
ARMED
READY
SHIFT
FUNCTION
WHEN LIT
7720P Emulation Template for Alpha Keypads
A
B
(A)
1
2
BS/ESC
OFF
AWAY
D
E
(B)
4
5
/
MAX
TEST
S
T
(C)
7
8
N / Y
INSTANT
CODE
SPACE
(D)
0
SHIFT
READY
(continued on other side)
C
3
STAY
F
6
BYPASS
X
9
CHIME
ENTER
#
6160-7720P-001-V0

Advertisement

loading

Summary of Contents for Honeywell VISTA-10P

  • Page 1 Otherwise, the call to the secondary number by the communicator after the alarm report will prevent the AAV from taking control of the telephone line, and the AAV Options: Same as for VISTA-10P. “Listen in” session cannot take place. Call Waiting Disable: 0 = call waiting not used UL: must use ADEMCO UVCM module;...
  • Page 2 [0]: For entering the number 0 [#] / ENTER [#] / ENTER: Press to accept entries No SHIFT function 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2009 Honeywell International Inc. ÊK0735V4SUPP%Š www.honeywell.com/security K0735V4SUPP 3/09 Rev. A...