Sanyo XHS3632 Service Manual page 72

Split system air conditioner
Hide thumbs Also See for XHS3632:
Table of Contents

Advertisement

3)
Compressor motor does not operate.
Does compressor motor magnetic
contactor (52C) actuate ?
Check resistance of compressor
motor winding.
Section
1
4)
Outdoor fan does not operate.
2
Are auxiliary relays (1Y)
normal ?
Is fan motor capacitor normal ?
3
Is there voltage output of
P.C.B. Ass'y for fan motor ?
4
Check resistance of fan motor
winding.
No
Yes
NG
Replace the compressor.
No
Yes
No
Yes
No
Yes
NG
Replace the fan motor.
Replace the compressor
motor magnetic contactor.
Replace the relays.
Replace the capacitor.
Replace P.C.B. Ass'y
in the outdoor unit.
– 72 –
4. Service procedures
0461_M_I
1148_THS_I
SM830076

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch2432Xhs2432Ch3632

Table of Contents