1-2 Major Component Specifications

(B) Outdoor Unit

MODEL No.
Source
Controller P.C.B. Ass'y
Control circuit fuse
Compressor
Model
Source
Nominal output
Compressor oil
Coil resistance (Ambient temperature 77 F)
Safety device
Overload relay models
Operating temperature
Operating ampere (at 77 F)
Run capacitor
Crank case heater
Refrigerant amount charged at shipment
High pressure switch
Set pressure
Fan
Number...diameter
Fan speeds
Fan motor
Model
Source
No. of pole ..... rpm (230 V, High)
Nominal output
Coil resistance
(Ambient temperature 68 F)
Safety device
Operating temperature
Run capacitor
Heat exchange
Coil
Rows ..... Fins per inch
Face area
W
cc
Open
F
Close
F
A
VAC,
F
VAC,
W
lbs.
(kg)
2
2
OFF lb/in
(kg/cm
)
ON lb/in
2
(kg/cm
2
)
in.
(mm)
W
BRN – WHT : 67.14 , VLT – YEL : 11.42
WHT – VLT
Open
F
Close
F
VAC,
F
ft.
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
– 13 –
1. Specifications
CH2432
230 - 208 VAC / 1 phase / 60 Hz
CR - CH2432 (Microprocessor)
250 VAC, 3 A
Rotary (Hermetic)
C - 2R160H6T
230 - 208 VAC / 1 phase / 60 Hz
1,700
800
C – R : 0.885 , C – S : 1.773
Internal type
297
9
198
20
400 VAC, 40 F
230 VAC, 30 W
R22 : 6.17 (2.8)
ACB - 1UB11
+ 28.44
+ 2.0
426.6
(30
)
+ 7.11
+ 0.5
341.3
28.44 (24
2.0)
Propeller
1 ... 18 - 3/32 (460)
2 (AUTO)
KFC6T - 91D6P
230 - 208 VAC / 1 phase / 60 Hz
6 ... 879
110
: 64.85 , YEL – PNK : 10.60
Internal type
248
9
171
27
440 VAC, 4 F
Aluminum plate fin / Copper tube
2 ... 14.1
6.78 (0.63)
1
2
3
4
SM830076