Important
Set the Operation Selector at the "ON" position. Other-
wise the unit will stop or will not run correctly.
CAUTION
Section
NOTE
1
During the test run, all of the 3 indicator lamps on the
indoor unit will flash.
During the test run, the air conditioner runs continu-
ously and the thermostat does not control the sys-
tem.
To protect the air conditioner from overloading, the
2
outdoor unit will not start running for 3 minutes after
power is applied or the air conditioner is turned off
and then back on.
When the air conditioner fails to start the test run, 1
or more of the 3 alarm indicator lamps on the indoor
unit will flash.
3
4
The TEST RUN switch is used
only for servicing the air
conditioner. DO NOT use this
switch for normal operation.
Otherwise, it may put stress
on the system.
– 100 –
4. Service procedures
SM830076