Adjusting Pilot Flame - Frymaster FMCFE Service & Parts Manual

Master jet cf series atmospheric gas fryers
Table of Contents

Advertisement

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS
1.3 Checking Burner Manifold Gas Pressure (cont.)
Non-CE Standard
for Incoming Gas Pressures
Gas
Natural
LP
4. If the measured manifold gas pressure does not match the appropriate pressure in the preceding
tables, remove the cap from the gas valve regulator and adjust to the correct pressure.

1.4 Adjusting Pilot Flame

1. On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the
pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to
decrease the length of the flame. Adjust the flame to a length of 1 to 1-½ inches (25 to 38 mm).
On Non-CE gas valves, remove this cap to
access Pilot Adjustment Screw.
2. On Non-CE valves, reinstall the pilot adjustment screw cap.
CHAPTER 1: SERVICE PROCEDURES
Minimum
Maximum
6" W.C.
14" W.C.
1.49 kPa
3.48 kPa
14.93 mbar
34.84 mbar
11" W.C.
14" W.C.
2.74 kPa
3.48 kPa
27.37 mbar
34.84 mbar
Honeywell Valve
(Non-CE Units)
Regulator Adjustment Screw Cap
Honeywell Valve
(Non-CE Units)
Non-CE Standard
for Burner Manifold Gas Pressures
Gas
Natural
LP
Honeywell Valve
(CE Units)
Pilot Adjustment Screw
Honeywell Valve
(CE Units)
1-6
Pressure
3.5" W.C.
.75 kPa
7.5 mbar
8.25" W.C.
2.0 kPa
20.0 mbar