Cleaning The Gas Valve Vent Tube; Checking The Burner Manifold Gas Pressure - Frymaster Enodis BIPH52/55 Service Manual

Gas fryer
Table of Contents

Advertisement

2. Remove any attached restraining devices and relocate the fryer for service accessibility.
3. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and
plug in the electrical cords. NOTE: To ensure the safe and efficient operation of the fryer
and hood, the electrical plug for the 120-volt line, which powers the hood, must be fully
engaged and locked in its pin and sleeve socket.
1.3

Cleaning the Gas Valve Vent Tube

1. Set the fryer power switch and the gas valve to the OFF position.
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease of removal.
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any
obstruction.
4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall the tube and bend it so that the opening is pointing downward.
1.4

Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
Honeywell
Pressure Tap Plug
Typical Non-CE
Valve Assembly
ON
OFF
Typical CE Valve
Assembly
1-5