Components of SCALANCE X-400
The following table shows the components of SCALANCE X-400:
Component
Basic device consisting
of
Backplane
Power module
DI module
Switch CPU
Two 1000BaseTX
interfaces
Twelve 100BaseTX
interfaces
Extender interface
Media module fiber-
optic 1000 Mbps
Media module
100 Mbps
Twisted pair extender
Media module extender
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03
Function
The power module con-
verts the 24 V input power
into the internal operating
voltage of the basic de-
vice.
There are eight digital in-
puts for feeding in exter-
nal signals.
The Switch CPU man-
ages the data traffic. The
CPU also has a serial and
an Ethernet port.
Expands the basic device
by two gigabit fiber-optic
ports.
Expands the basic device
by two fast Ethernet fiber-
optic ports.
Expands the basic device
by eight fast Ethernet
ports with RJ-45 jacks.
Expands the basic device
by four slots for fast
Ethernet media modules.
System Description of SCALANCE X-400
Figure
For example SCALANCE X414-3E
For example MM492-2
For example MM491-2
EM495-8
EM496-4
23