6.8.1

Startup Behavior of the SCALANCE X414-3E

During device startup, the red LED on the power module signals the current status
of the device. For more detailed information, refer to the following table:
During de-
vice startup
During ope-
ration
Figure 6-23
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03
LED on
Device starting up
or fault occurred
Fault occurred
Fault LED on the power module
Installation and Commissioning
LED off
Device startup
completed without
problems
Problem-free op-
eration
LED flashes
Keyboard entry
over serial inter-
face or bad firm-
ware image
107