Glossary
Connection monitor-
ing
Digital input
Dispersion
Display Mode
(DMode)
ESM
Fault mask
FO port
Full duplex
Half duplex
Latency
Load Containment
140
With regular link test pulses, SCALANCE X-400 monitors the con-
nected TP and FO cable segments for short-circuits or interruptions.
The SCALANCE does not send data to a segment from which it is not
receiving link test pulses.
A digital input is used to acquire binary file information. A state change
can be logged in the Log Table or reported by E-mail or traps. The
voltage levels between – 30 V and + 3 V correspond to logical state "0",
voltage levels between + 13 V and + 30 V correspond to logical state
"1".
Broadening and distortion of light pulses in fiber-optic cable due to
signals arriving at different times. On multimode FOC, the distortion of
the output signal is greater than with single mode FOC.
Display mode that indicates various statuses (port status, power moni-
toring activated etc.). The modes can be switched over using a button
on the Switch CPU.
Electrical Switching Module – SIMATIC NET Ethernet switch with elec-
trical ports.
Specifies the desired status (good status). Deviations from this occur-
ring during operation are handled as faults.
Fiber-Optic Port
Two-way simultaneous - both communication partners can send and
receive at the same time.
Two-way alternate transmission mode- it is only possible to either send
or receive over the interfaces at any one time.
Latency specifies the time taken by frames to pass through a switch.
This does not include the time required for buffering frames.
With its filtering functions, a switch makes sure that local data traffic
remains local. The local network load of a segment is contained in the
originating segment and does not represent extra load on the remain-
der of the network.