Install the GIPH or GIPU8 IP Interface PCB (optional)
When the GIPH1 or GIPU8 or an MIPU card is installed, a GCOCIH1 (four circuit CO Line
interface) cannot be installed. For MIPU installation refer to
Interface PCB (optional)" on page
1. Turn off system power.
2. In the CIX40 cabinet, remove the two screws and the PCB stopper
3. If the GCTU2 is installed remove it.
4. Install the GIPH, GIPU8, or MIPU into the GMAS (sub-motherboard) (see
1-11
and
Figure
5. If you are installing a GVPH insert that card now. Otherwise, refer to
(Processor)" on page
Note To program GIPH1, refer to the Strata CIX Programming Manual Volume 1 and use
eManager.
Note When set to G.729A with the echo canceller tail length set to 32ms the GIPH operates as a
six channel resource,
Licenses are required for IP Telephone and Strata Net IP. Use eManager R5.00-A12, or later, to
apply the necessary licenses to the GCTU2 for GIPH, GIPU8, or MIPU operations.
Figure 1-20 GIPH1 Card
Strata CIX40 R3 Installation & Maintenance
1-36.
1-21).
38.
05/10
CIX40 Installation
Detailed PCB Installation
"Install the MIPU 16 or 24-Channel IP
(Figure
1-21).
Figure
1-10,
"Install the GCTU2
Reset switch
Serial port
HB LED
LAN Port
Figure
1-35