Table 1-4
provides a summary of the electrical and environmental characteristics.
Table 1-4 Summary of Electrical/Environmental Characteristics
Specification
Input AC
AC frequency
AC input current
Operating temperature
Operating humidity
Storage temperature
Specification
Input DC
Standard Telephone Ring Circuit (GMAU2, GMAU3 and GMAU4, and GSTU1)
Ring Voltage
Ringing capability
Strata CIX40 R3 Installation & Maintenance
CIX40 Primary Power (Power Supply Specification)
R1 and R2 Hardware
105~125VAC
50/60 Hz
1.5A maximum (100 VAC)
Environmental Specifications
32~104° F (0 ~40° C)
20~80% relative humidity without condensation
-4~140° F (-20~60° C)
Power
R1 and R2 Hardware
15V use the factory-shipped AC
adapter (SQ60W15P-00)
180V p-p square wave
1 REN, 1 circuit - one telephone per circuit
05/10
CIX40 Installation
Site Requirements
R3 Hardware
105~125VAC
50/60 Hz
1.7A maximum (100 VAC)
R3 Hardware
-27V use the factory-shipped
AC adapter (ACADP40-1A)
1-9