Detailed PCB Installation
Table 1-9 GMAU2 Controls, Switches and Indicators
Control/Indicator/
Connector
SW400
SW500
SW600
1-26
Type of Component
SW1
2-position slide switch
2-position slide switch
CD6
LED
TB1
Terminal with screw
TB3
Terminal with screw
50-pin Amphenol
P1
connector
P3
44-pin DIN connector
16-pin female
P4
connector
13-pin female
P5
connector
10-pin female
P6
connector
13-pin female
P7
connector
10-pin female
P8
connector
P9
6-pin female connector
P10
3-pin connector
P11
3-pin female connector
P400
P500
Modular connector
P600
F1
2.0A Fuse
Description
Power Switch:
[STANDBY] = no DC power supply.
[ON] = DC voltage supplied. [ON]
activates the reserve power from HPFB-6
battery pack.
3dB Pad switch
Power indicator;
Lit when SW1 is [ON], turned on and AC
power or Reserve power is present.
Dark when SW1 is [STANDBY], turned off.
Grounding for HPFB-6 external battery
Grounding for CIX40 system, connect to
earth ground
DKT, SLT and Power Failure Transfer
interface
GMAS (sub-motherboard) interface
GCDU2 DKT and loop start interface
GSTU1 standard telephone interface
GCDU2 interface
HPFB-6 external battery interface
GSTU1 standard telephone interface
Interface for CO Line circuit (CO1/Cct1)
Interface for CO Line circuit (CO2/Cct2)
Interface for CO Line circuit (CO3/Cct3)
-24VDC Over current protection
Strata CIX40 R3 Installation & Maintenance