Detailed PCB Installation
GCOCIH1 CO Line Interface PCB Installation (optional)
The GCOCIH1 provide four loop start CO Line circuits. The GCOCIH1 card plugs into the GMAS
sub-mother board. This is the slot adjacent to the voice mail card. When the GCOCIH1 card is
installed an IP interface card cannot be installed in the system.
Table 1-14 GCOCIH Controls and Switches
Control/Connector
SWxxx
Pxxx
Cct 1/2
Cct 3/4
When a GCOCIH1 card is installed, a GIPH1 or MIPU cannot be installed.
1. Turn off system power.
2. In the CIX40 cabinet, remove the two screws and the PCB stopper
3. If the GCTU2 is installed remove it.
4. Install the GCOCIH into the GMAS (sub-motherboard) (see
Figure
5. If you are installing a GVPH insert that card now. Otherwise, refer to
(Processor)" on page
Note The GCOCIH1 cards must be separated to set the PAD switches.
Figure 1-19 GCOCIH with CCOCIS PCB Assembly
1-34
Type of Component
2-position slide switches
connector
P3
Connector
RJ connector on GCOCIH
RJ connector on CCOCIS
1-21).
38.
Cct 3/4
Description
3dB Pad switch per circuit
Interface to CCOCIS
Interface to GMAS
CO LIne circuits 1 and 2
CO LIne circuits 3 and 4
(Figure