Configuration

The two primary considerations in system configuration are Card Slot Use and Power Factor.

Card Slot Use

The card slots can each support up to 32 ports. There are a few card position requirements based
on cable lengths. These are discussed in detail in the Strata CIX Installation Manual. These
requirements do not affect the system capacities.
In general, determine the number and type of stations needed, the number and type of trunks, and
any additional requirements. Other requirements include voice mail, power fail transfer, tie lines,
etc. The total number of ports required must not exceed 192.
Processor
Card
Figure 5
Two Cabinet CIX

Power Factor

Power Factors for the CIX200 circuit cards are shown below. For all others please refer to the
Installation and Maintenance Manual.
• LCTU1A: No effect on Power Factor calculations
• MIPU: PF = 0.2
• LIPU-X1A: PF = 2.6
• LIPS-X1A: PF = 1.9
• LSLU1A: PF = 1.5
There are no Power Factor considerations for the new IP Telephones (IPT2010/2020/2008), add-on
modules (IADM2020 and IDSS2060), and DSS consoles because the power is not supplied from
CIX200 cabinet.
The system (-24V) Power Factor is 67 per cabinet. There is no +5V power factor consideration for
the CIX200. For an example on how to use the System Power Factor and for worksheets, refer to
the Strata CIX Installation and Maintenance manual.