Axu-Cp, Axu-Cp/Pb, Axm-Cp, And Axm-Cp/Pb - AMX AXT-CP Instruction Manual

Color passive-matrix lcd touch panels (firmware version g2 or lower)
Hide thumbs Also See for AXT-CP:
Table of Contents

Advertisement

Figure 205
IC locations on the circuit card
132
Memory Upgrade
Gently tilt the circuit card down towards the connector side and pull backwards
5.
until you clear the connector housing. Then, slowly rotate the circuit card
backwards until you can lay it down flat with the IC exposed.
Carefully pry the 256K ICs out of the 32-socket connectors and insert the new 1
6.
MB ICs.
Rotate the circuit card back to the original position and place it in the touch
7.
panel housing. Align the screw hole and insert the Phillips-head screw and
tighten.
Place the bottom panel onto the touch panel and align the screw holes. Insert the
8.
seven Phillips-head screws and tighten.
Plug all connectors back into the touch panel.
9.

AXU-CP, AXU-CP/PB, AXM-CP, and AXM-CP/PB

Figure 205 shows the location of the ICs on the touch panel's circuit card. Install the
1 MB ICs into the touch panel:
Discharge the static electricity from your body by touching a grounded object.
1.
32-socket IC 1 and 2