Setting Up Channels On The Triton T1/E1 Board; Triton T1/E1 Boards - Altigen MAXCS ACC 6.0 Administration Manual

Table of Contents

Advertisement

If two MAXCS systems are connected back-to-back with a T1/E1 span, the System
Clock Master check box must be checked for only one of the T1/E1 boards.
If two T1/E1 boards in the same MAXCS system are connected back-to-back with a
T1/E1 span, the System Clock Master check box must be checked for the T1/E1
board that has not been designated by the CT-Bus setting as the system's master
clock to drive the CT-Bus.
For all back-to-back cases, the CT-Bus Clock Configuration should be set to
Important:
"Manual," and the board that is connected to the board configured as the
back-to-back clock master must be designated at the CT-Bus master.

Setting up Channels on the Triton T1/E1 Board

This section discusses setting up T1 CAS, T1 PRI, E1 CAS, or E1 PRI channels on the
Triton T1/E1 board.
Click the Protocol button in the T1 or E1 configuration dialog box (see Figure 8 on
page 121) to open the Protocol Configuration window, shown below. The Triton T1/
E1 Board can be configured to either CAS or PRI through the configuration options in the
window.
The CH -> Type list on the left side of the window displays the channel types.
In a tie-trunk configuration, set the trunks to "Out of Service" before changing the
Note:
trunk type from T1 to PRI or vice versa. Otherwise, the system will generate
garbage call records to your internal or external logger service. See "Setting
General Trunk Attributes" on page 146 for details.
Figure 9. T1 PRI Protocol Configuration dialog box (top half)
Chapter 11: Board Configuration
MAXCS ACC 6.0 Administration Manual 125