Summary Of Ul Requirements - Gemini GEM-P9600 Installation Instructions Manual

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P9600:
Table of Contents

Advertisement

WI742E 2/04
Compatible Smoke Detectors
UL Compatible Smoke Detectors (Providing UL Recognition or Listing)
4 Wire Smoke Detectors
Manufacturer
Model
Gentex
812, 812T, 812P,
812PT, 812PH,
8120, 8120T,
8120P,
8120PTY, 8120-PH
Hochiki
SLG-12 w/YBC-RL4-RA base N/A
NAPCO
FW-4
Sentrol/ESL
445AT, 445C,
445CT, 445CR,
445CRT
System Sensor 1112, 2112,
21112T, 211TSRB
1412TH, 2412TH
2312/24T, 1412,
Note: Subtract total smoke-detector alarm current
from available standby current.
Note: Any normally-open devices that do not require power from the control panel may be used (such as
pull stations, waterflow and thermostats), if acceptable to the authority having jurisdiction.

SUMMARY OF UL REQUIREMENTS

Residential
!
Recognized Limited-Energy Cable for initiating, indicating and supplementary circuits.
!
Initiating loops supervised if longer than 3 feet
!
FT2200 End-of-Line Relay for Fire (if using 4-wire smoke detectors)
!
Minimum alarm timeout of 5 minutes
!
Maximum exit time: 60 seconds
!
Maximum entry time: 45 seconds
!
Do not program "Swinger Shutdown", "Force Arming", "Selective Bypass", "Group Bypass", or "50 ms Loop
Response"
!
"Abort Delay" may not exceed 45 seconds
!
Program "Disable Callback Download"
!
Automatic dialer may not dial a police station number that has not been dedicated for such service
!
System must be tested at least weekly under AC/battery and Battery-Only conditions
!
Replace the rechargeable battery at least every 5 years
!
If the battery is heavily discharged, replace it or have it tested by a qualified technician
!
For silent panic, connect only to UL-listed holdup devices
!
All zones must be programmed for "Priority"
!
Do not program any zones for "Keyswitch Arming"
!
System must be serviced at least once every year
!
Residential Fire and Combination Residential Fire & Burglary must program "Residential Fire"
!
Keypad Expansion (EZM) Zones are not to be used as fire zones
L
NAPCO Security Systems
2 Wire Smoke Detectors
Base
Manufacturer
N/A
NAPCO
N/A
Sentrol/ESL
N/A
N/A
N/A
System Sensor
N/A
N/A
N/A
N/A
Note:
Voltage Rating: 8.5–13.3 VDC
N/A
Maximum Number of Detectors: 10
N/A
N/A
N/A
Model
Base
FW-2
N/A
711U, 712U,
701U, 702U,
721U, 721UT,
702RE, 702RU
722U, 731U, 732U
1100, 1151,
N/A
1400, 2100,
N/A
2100T, 2100S,
N/A
2100TS, 2151,
N/A
2400, 2400TH
N/A
X
GEM-P9600 Installation Instructions
!
Page 9