Time Selection
The following times are programmable:
(1)
TIME
RESET OUTPUT
AUXILIARY OUTPUT
AUXILIARY OUTPUT
ACCESS CONTROL TIME
BURGLARY OUTPUT
PULSE-BURG OUTPUT
FIRE OUTPUT
ABORT DELAY
CHIME TIME
AC-FAIL REPORT DELAY
EXIT DELAY
ENTRY DELAY 1
ENTRY DELAY 2
TELCO LINE-TEST DLY
AUTO DISARM /
REARM DLY
SENSOR-WATCH TIME
DISARMED HOURS
*Blank.
Note: If both programming locations are left blank, refer to the notes in the Time Selection table for feature timeout.
To select a time up to 15 seconds, 15 minutes, 15 hours, or 15 days, program the respective entry into the second box only; do
not program the first box. To select a time greater than 15 seconds, 15 minutes, 15 hours or 15 days, program both boxes as follows:
1. For the feature selected, choose an appropriate time in units shown (all seconds, minutes, hours, or days — not minutes
and seconds, etc.).
2. Divide the time chosen by 16. Enter the quotient in the 1st BOX and the remainder in the 2nd BOX.
3. Check entries by adding the contents of the 2nd BOX to 16 times the contents of the 1st BOX. (Remember that a "zero"
entry represents 10.)
Example. Program Entry Delay 1 for 1 minutes.
1. Entry Delay 1 is in units of seconds, thus delay time is 90 seconds.
2. Divide by 16: 90/16 = 5 (quotient) + 10 (remainder).
3. Enter the quotient in the 1st BOX and the remainder in the 2nd BOX
4. Check entries (remember, a "0" entry = 10): (16x5) + 10 = 90
TouchTone Dialing Only
Rotary Dialing Only
TouchTone Dialing with Rotary Backup
Select TouchTone Dialing Only if the subscriber has TouchTone service. TouchTone dialing is faster than rotary dialing, but not
always as reliable.
For the communicator to use TouchTone on all dial attempts, program TouchTone Dialing Only. To use TouchTone on the first
attempt with subsequent Rotary dial, program TouchTone Dialing with Rotary Backup. TouchTone Dialing Only will override Touch-
Tone Dialing with Rotary Backup if both are selected. Note that if Backup Reporting is also selected, the communicator will alternate
between TouchTone and rotary dial to reach Telephone 1, then Telephone 2. See Backup Report on Telco 2.
Trouble
An abnormal zone condition (a break in a normally-closed loop; a short on a normally-open loop; or either on an end-of-line-
resistor supervised loop) when disarmed.
Trouble on a Burglary Zone is automatically displayed at the keypad unless Disable Zone Fault Scrolling (Auto Status) is pro-
grammed. If a Burglary Zone is in trouble, it will go into alarm about 10 seconds after arming. However, if Auto Bypass is pro-
grammed, the keypad will beep upon arming (does not apply to selective- or group-bypassed zones).
X
GEM-P9600 Installation Instructions
UNITS
MAX. PROG. TIME
MIN.
UNTIMED
MIN.
UNTIMED
SEC.
4 MIN, 15 SEC (255 SEC)
MIN.
UNTIMED
MIN.
UNTIMED
MIN.
UNTIMED
SEC.
4 MIN, 15 SEC (255 SEC)
¼ SEC.
63.25 SEC (255 QTR-SEC)
10 MIN.
42 HR, 30 MIN (2550 MIN)
SEC.
4 MIN, 15 SEC (255 SEC)
SEC.
4 MIN, 15 SEC (255 SEC)
SEC.
4 MIN, 15 SEC (255 SEC)
15 SEC.
4 MIN, 15 SEC (255 SEC)
MIN.
4 HR, 15 MIN (255 MIN)
255 HOURS
Time t:
0
1
2
3
Entry:
*
1
2
3
(1)
NOTES:
The output used for Burglary must be at least 4 minutes
in Residential UL installations, 15 minutes in Commercial UL instal-
(2)
lations.
If both locations are left blank, this feature will remain ac-
(2)
tive until the system is disarmed. When both locations are pro-
grammed "F", maximum time will be 4 hours, 15 minutes (255 min-
(2)
(3)
utes).
If both locations are left blank, this feature will not activate
(timeout = 0).
Maximum Entry Delay = 45 sec.
blank, delay will default to 10 sec.
(1)(2)
(accumulated between armed periods).
(1)(2)
(2)
Any timeout up to those shown in the foregoing table may
be programmed. Note that each of the above times is pro-
(3)
grammed in two locations. The first location has an as-
(3)
signed time factor of 16, the second a time factor of 1.
(4)
(4)
(4)
(5)
(6)
4
5
6
7
8
9
10 11 12 13 14
4
5
6
7
8
9
0
B
(4)
In UL installations: Maximum Exit Delay = 60 sec;
(5)
If programming locations are left
(6)
Time in units of disarmed hours
1st BOX
2nd BOX
tx16
tx1
15
C
D
E
F
L
NAPCO Security Systems
WI742E 2/04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem-p9600

Table of Contents