Download Print this page

Amana RSS Service Manual page 82

Amana gas range service manual

Advertisement

PROBLEMS
5.
Unit continues to spark
after it is turned off.
PROBLEMS
1.
Yellow tipped burner flame. A.
2.
Flame blows away from
burner.
4.
Floating (lazy) flame.
5.
Gas smell in kitchen.
POSSIBLE CAUSE
A.
Shorted valve switch.
B.
Switch has been pulled up
and off of fixed position on
valve so that it is not turned
to off position with valve
stem.
POSSIBLE CAUSE
Too little primary air.
B.
Burner head bent.
C.
Of using L.P. Gas, range
may not be properly
converted.
A.
Too much air.
B.
Gas pressure too hign.
C.
Heavy draft around cooktop
area.
A. Blocked flue, blocked
burner.
A.
Leak in pipe joints.
B.
Valve leak.
C.
Regulator plug loose.
CORRECTION
A.
Replace switch.
NOTE: If shorting is cau
customer should be advi
Carefully reposition switc
B.
from off to high several ti
broken.
CORRECTION
A.
Open air shutter on burne
B.
Level burner head.
C.
Check for proper L.P. co
A.
Slightly close air shutter t
B.
Check pressure at orifice
C.
Eliminate source of draft.
A. Check for possible block
A.
Check gas connections
needed.
B.
Check valve and replace
C.
Check and tighten regula

Advertisement