PROBLEMS
1. Burners will not ignite.
"SPARK" at top burner
ignitors.
2. Burner will not ignite. No
"SPARK" at top burner
ignitors. Burner knob
pushed down and held in
"LIGHT" position.
3. An intermittent or occasional
spark after unit is turned off.
POSSIBLE CAUSE
A.
Burner venturi, burner cap
or burner ignition ports
clogged.
B.
Air shutters out of
adjustment.
C.
Burner flame not correctly
adjusted (LP GAS)
D.
Poor ground on ignitor
grounding bracket or gap
between ignitor and bracket
dimple is too large.
Low gas pressure
E.
A.
No 120 VAC to range.
B.
Micro Switch contacts
not closing.
C.
Faulty wiring or bad
connection.
D.
Inoperative spark module.
E.
Ignitor ceramic dirty, spark
gap out of adjustment.
F.
Cracked or broken ignitor
extension lead.
A. Crossed polarity. When
polarity is correct, no
voltage is present at neutral
to ground and no voltge to
spark module with switch at
off.
CORRECTION
A.
Clean burner venturi, or i
B.
Adjust air shutter accord
instruction.
C.
Adjust burner flame acco
information in installation
D.
Tighten bracket and /or
0").
E.
Check pressure (6" WCP
for LP).
A.
Check electric at wall ou
B.
Check micro switch posi
micro switch contacts (S
C.
Check wiring against app
all terminals and connec
Check module according
D.
Replace module.
Clean ceramic, check gr
E.
Replace ignitor.
F.
A. With all switches in the "
voltage at the "N" termin
ground. If voltage is pres

Advertisement

loading