BASIC TIMER and TIMER 0

Capture Mode

In capture mode, a signal edge that is detected at the T0CAP pin opens a gate and loads the current counter
value into the T0 data register. You can select rising or falling edges to trigger this operation.
Timer 0 also gives you capture input source: the signal edge at the T0CAP pin. You select the capture input by
setting the value of the timer 0 capture input selection bit in the port 3 control register, P3CON.2, (set 1, bank 0,
EFH). When P3CON.2 is "1," the T0CAP input is selected. When P3CON.2 is set to "0", normal I/O port (P3.0) is
selected.
Both kinds of timer 0 interrupts can be used in capture mode: the timer 0 overflow interrupt is generated
whenever a counter overflow occurs; the timer 0 match/capture interrupt is generated whenever the counter value
is loaded into the T0 data register.
By reading the captured data value in T0DATA, and assuming a specific value for the timer 0 clock frequency,
you can calculate the pulse width (duration) of the signal that is being input at the T0CAP pin (See Figure 10-6).
P3.0/T0CAP
10-8
CLK
Timer 0 Data Register
T0CON.5
T0CON.4
Figure 10-6. Simplified Timer 0 Function Diagram: Capture Mode
8-bit Counter
Pending
(T0CNT)
Pending
(T0DATA)
S3F80P5_UM_ REV1.00
Interrupt
Enable/Disable
(T0CON.2)
IRQ0 (T0OVF)
IRQ0 (T0INT)
Interrupt
Enable/Disable
(T0CON.1)