Korg TRITON proX Manual page 125

Music workstation / sampler
Hide thumbs Also See for TRITON proX:
Table of Contents

Advertisement

switched. However, the program changes for each timbre
will be affected by the setting of the "Enable Program
Change" parameter (Combination P3: 3–1a).
When you switch combinations, a program change message
will be transmitted on the global MIDI channel, and also
transmitted simultaneously on the channel of timbres whose
"Status" (Combination P0: 0–1f) is set to EXT or EX2.
In Sequencer mode, incoming program change messages on
a channel that corresponds to a track whose "Status"
(Sequencer P2: 2–1a) is set to INT or BTH will switch pro-
grams on that track. When you select a song or playback
sequencer data, program changes will be transmitted on the
channels of tracks whose "Status" is set to BTH, EXT, or
EX2.
Unchecked: Program changes will not be transmitted or
received.
Enable Bank Change
Checked: The Bank Select control change message will be
transmitted together with program change messages. This is
valid when "Enable Program Change" is checked.
Unchecked: Bank Select messages will not be transmitted or
received.
When recording on the internal sequencer, bank select
messages will be recorded regardless of this setting.
However for playback, this setting will apply.
Enable Combination Change
Checked: When in Combination P0: Play, an incoming pro-
gram change message on the global MIDI channel set by
"MIDI Channel" (1–1a) will switch combinations. This is
valid when "Enable Program Change" is checked. An
incoming program change on a channel other than the glo-
bal MIDI channel will switch the program of any timbre that
matches that MIDI channel.
Unchecked: An incoming program change message on the
global MIDI channel will switch the program of any timbre
whose "MIDI Channel" (Combination P2: 2–1a) matches the
global MIDI channel. The combination will not be switched.
The program changes for each timbre will be affected by the
setting of the "Enable Program Change" parameter (Combi-
nation P3: 3–1a).
Enable After Touch
Checked: MIDI after touch messages will be transmitted
and received.
Unchecked: MIDI after touch messages will neither be
transmitted nor received.
When recording sounds that do not require the use of after
touch, you can uncheck this parameter to save memory.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
after touch data; i.e., after touch will be transmitted via MIDI.
The TRITON's keyboard transmits only channel after touch;
it does not transmit polyphonic after touch. However, since
the TRITON does support polyphonic after touch as an
Alternate Modulation Source (AMS), it can receive poly-
phonic after touch to control individual notes.
Enable Control Change
Checked: Control change messages will be transmitted and
received.
Unchecked: Control change messages will neither be trans-
mitted nor received.
This setting has no effect when you use the internal
sequencer to playback sequence data that was recorded with
control change data; i.e., control changes will be transmitted
via MIDI.
Enable Exclusive
Checked: System exclusive data will be transmitted and
received. Check this setting when you wish to use a con-
nected computer etc. to edit the TRITON, or vice versa.
Unchecked: System exclusive data will neither be transmit-
ted nor received. Normally you will leave this unchecked.
However, system exclusive data will be transmitted and
received while the page menu commands ("Dump Pro-
gram"–"Dump All") of this page are displayed.
1–1: Page Menu Command
M
1–1A: Dump Program
1–1B: Dump Combination
1–1C: Dump Drum Kit
1–1D: Dump Arpeggio Pattern
1–1E: Dump Global Setting
1–1F: Dump Sequencer
1–1G: Dump All
These commands allow the TRITON's data to be transmitted
to another connected TRITON, MIDI data filter, or computer
in the form of system exclusive data.
Select the desired command (refer to the following table),
and a dialog box will appear.
If you selected a command other than "Dump All" (1–1G),
select the bank or timbre etc. of the data to be dumped. Then
press the OK button.
Dump Program
Programs of all banks, programs of the
specified bank, one program
Dump Combination
Combinations of all banks, combinations of
the specified bank, one combination
Dump Drum Kit
All drum kits, One drum kit
Dump Arpeggio Pattern All arpeggio patterns, One arpeggio pattern
Dump Global
Global settings (except for the Drum Kits
and User Arpeggio Patterns of Global
mode)
Dump Sequencer
All sequences
Dump All
All banks of programs + combinations +
drum kits + arpeggio patterns + global set-
tings + sequences
Transmission
Do not touch the TRITON's switches or turn off the
power while data is being transmitted.
Data dump transmission procedure
1 Connect the TRITON to the device that will receive the
data dump.
If you are using a computer that is able to receive MIDI
exclusive messages, connect the serial port of the com-
puter to the TO HOST connector of the TRITON.
0–1A
1–1A
1–1B
1–1C
1–1D
1–1E
1–1F
1–1G
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Triton proTriton

Table of Contents