Removing And Replacing The Power Supply; Removing The Power Supply - HP Integrity rx1620 Maintenance Manual

Hide thumbs Also See for Integrity rx1620:
Table of Contents

Advertisement

Figure 55
4.
The disk drive is now correctly installed.

Removing and Replacing the Power Supply

The power supply is located at the left front of the server chassis. The power supply is a field
replaceable unit (FRU).
WARNING!
disconnected from the server prior to removing or replacing the power supply.
Voltages are present at various locations within the server whenever an AC power source is
connected. This voltage is present even when the main power switch is in the off position.
Failure to observe this warning could result in personal injury or damage to equipment.
CAUTION:
ESD safety precautions could result in damage to the server.

Removing the Power Supply

To remove the power supply, perform the following steps:
1.
Remove the cover. See
2.
Remove the power supply fan unit from the chassis. See
(page
46).
3.
Slide the power supply forward in the chassis releasing the power supply connection to the
power distribution unit.
Ensure that the system is powered-down and all power sources have been
Observe all ESD safety precautions before attempting this procedure. Failure to follow
"Removing and Replacing the Cover" (page
30).
"Removing and Replacing Fan Units"
Removing and Replacing the Power Supply
59

Advertisement

Table of Contents
loading

Table of Contents