Optional Remote Control; Wiring; Final Check - Regency F37-LPG Owners & Installation Manual

Freestanding gas stove
Table of Contents

Advertisement

OPTIONAL
REMOTE CONTROL
Use the Regency
®
Remote Control Kit ap-
proved for this unit. Use of other systems may
void your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location, use Thermostat Wire Table.
2) Connect the wires as per the wiring diagram
above.
CAUTION
Do not connect the millivolt remote
control wires to the 240V wires.
This heater does not require a 240V A.C. supply
for the gas control to operate. A 240V A.C. power
supply is needed for the fan/blower operation.
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
®
F37 Regency
Rear Flued Room Sealed Freestanding Gas Heater
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the
remote receiver to "remote"
mode. The remote control is now ready for
operation.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
15.24
16 GA.
9.75
18 GA.
6.10
20 GA.
3.66
22 GA.
2.71

WIRING

Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.
WARNING: Electrical Grounding Instructions
INSTALLATION

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
CAUTION
m
Any alteration to the product that causes
sooting or carboning that results in damage
m
to the exterior facia is not the responsibility
m
of the manufacturer.
m
m
CAUTION: Label all wires prior to dis-
connection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

F37-ng

Table of Contents