I. Specifi cations
A. Electrical and Refrigerant Data
The nameplate provides electrical and refrigerant data. The nameplate is located on the
right side panel. For certifi cation marks, see the nameplate.
We reserve the right to make changes in specifi cations and design without prior notice.
Model Number
AC Supply Voltage
Compressor
Pump
Fan
Other
Maximum Fuse Size
Max. HACR Breaker
(USA Only)
Max. Circuit Breaker
(Canada Only)
Minimum Circuit Ampacity 20 AMPS
Design Pressure
Refrigerant
Single Phase
KMD-410MAH
115/60/1
115-120V 5.1RLA 50.0LRA 115V-120V 5.1RLA 50.0LRA
120V 0.42FLA 23W
120V 0.50FLA 60W
115-120V 0.15A
20 AMPS
20 AMPS
20 AMPS
HI-467PSI
LO-206PSI
R404A 18.3 oz.
5
KMD-410MWH
115/60/1
120V 0.42FLA 23W
--- --- ---
115-120V 0.15A
20 AMPS
20 AMPS
20 AMPS
20 AMPS
HI-467PSI
LO-206PSI
R404A 14.1 oz.