12) Turn on the power supply to start the washing process.
13) Turn off the power supply after 30 minutes.
14) Remove the front panel.
15) Move the service switch to the "DRAIN" position.
16) Replace the front panel in its correct position and turn on the power supply for 2
minutes.
17) Turn off the power supply and remove the front panel.
18) Move the control switch to the "ICE" position.
19) Replace the front panel in its correct position.
20) Turn on the power supply to fi ll the water tank with water.
21) Turn off the power supply after 3 minutes.
22) Remove the front panel.
23) Move the control switch to the "SERVICE" position. Move the service switch to the
"WASH" position.
24) Replace the front panel in its correct position.
25) Turn on the power supply to rinse off the cleaning solution.
26) Turn off the power supply after 5 minutes.
27) Remove the front panel.
28) Move the service switch to the "DRAIN" position.
29) Replace the front panel in its correct position and turn on the power supply for 2
minutes.
30) Turn off the power supply.
31) Remove the front panel.
32) Repeat steps 18 through 31 three more times to rinse thoroughly.
Note: If you do not sanitize the icemaker, go to step 14 in "Sanitizing Procedure."