Ice Machine
The icemaker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
Remove the Front Panel, move the
OFF. After 3 min., move the
replace the Front Panel.
2
After 3 min., remove the Front Panel, move the
control switch
to OFF. This removes the cubes from
the evaporator. Replace the Front Panel.
3
Remove all ice from the dispenser unit/ice storage bin
ATTENTION! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the ice.
Cleaning:
Water Tank
Insulation Panel (B)
Front of icemaker
4
Remove the Front Panel, move the
DRAIN. Move
control switch
Front Panel.
5
After 2 minutes, remove the Front Panel, move the
control switch
to OFF.
6
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Insulation Panel (A) and pour cleaning solution into
the water tank.
KMD-410, 460, 530
Scale Away
9.5 fl. oz (281 ml)
Warm Water
1.8 gal. (6.8 l)
7
In bad water conditions, a more thorough cleaning may
be required. Move
control switch
the power supply. Dilute 5 oz. of Scale Away to 1
gallon of warm water. Remove and clean the float
switch assembly (see
water supply tubes, spray tubes, water tank, and pump
motor and float switch assembly. Rinse thoroughly,
then replace in their correct positions. Turn the power
supply back on. Otherwise, continue to Step ❽.
#51009 | 4.28.2017
Cleaning & Sanitizing
control switch
control switch
to ICE, then
Top
Tech Support: 1.800.233.1940
Right
Side
Control Switch
Service Switch
Thumbscrews
service switch
to SERVICE. Replace the
to OFF, then turn off
Float Switch Cleaning
on back),
Tech Support: 1.800.233.1940
to
3
min.
.
to
After 2 min.
 continued on the back...
KMD-410MAH, MWH, MRH
KMD-460MAH, MWH, MRH
KMD-530MAH, MWH, MRH
ATTENTION!
Do not leave icemaker
3
unattended when panels are off
min.
AMMONIA
Cleaners
Sanitizing:
• Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
KMD-410, 460, 530
Bleach
0.9 fl. oz (27 ml)
Warm Water
1.8 gal. (6.8 l)
* Use bleach without additives.
• Remove the front panel &
insulation panel (A)
• Pour the sanitizing solution
into the water tank
• Replace all the panels, except
the front panel
• Move
service switch
WASH and
control switch
SERVICE, replace the front
panel
• After 15 minutes, remove
front panel
• Move
service switch
replace the front panel
• After 2 minutes, remove
front panel
• Move
control switch
15
16
17
to
to
18
to DRAIN,
19
to OFF
Page 1

Advertisement

loading

Summary of Contents for Hoshizaki KMD-410MAH

  • Page 1 After 2 minutes, remove the Front Panel, move the After 2 min. control switch to OFF. • After 15 minutes, remove Dilute Hoshizaki Scale Away with warm water (see Table below). front panel Remove the Insulation Panel (A) and pour cleaning solution into • Move the water tank.
  • Page 2 Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep KMD-410M_H:  sanitizing continued… KMD-460 & 530M_H: Loosen the two thumbscrews securing the Loosen the two thumbscrews on the pump insulation RINSE 1: (Steps 20-22) pump motor bracket.

This manual is also suitable for:

Kmd-410mwhKmd-410mrhKmd-460mahKmd-460mwhKmd-460mrhKmd-530mah ... Show all