Tube Channel Assembly Replacement - Quadra-Fire VOYA-GRAND-MBK Owner's Manual

Voyageur grand wood insert automatic combustion control (acc)
Hide thumbs Also See for VOYA-GRAND-MBK:
Table of Contents

Advertisement

VOYAGEUR GRAND Wood Insert
G. Tube Channel Assembly Replacement
Removing Tube Channel Assembly
1. Remove the 3 right side bricks.
2. Remove the baffle protection channel by bending back the tabs
using needle nose pliers located at the right and left side of the
protection cover. Lift the cover up slightly and pull toward the
front and out of the firebox. Figure 24.1.
3. Locate the 2 channel nuts and two bolts inside of chamber and
remove using a 7/16 socket wrench. Figure 24.2.
NOTE: Soak the bolts with penetrating oil for at least 15 minutes
before trying to remove them.
4. Slide the tube channel assembly all the way to left until it is off the
threads. Drop the right side down, then slide the assembly back
to right. Figure 24.3.
5. The ceramic blanket and both baffle boards can be removed at
the same time you remove the tube channel assembly.
6. When the tube channel assembly is free of the left side sup-
port, rotate clockwise and pull assembly, blanket and baffles out
through the front opening.
7. Re-install in reverse order.
Tube
2 Tube Channel Nuts
Channel
Assembly
Figure 24.3
Page 24
Ceramic Blanket
Baffle
Protection Channel
7075-166C
Bend Back Tabs
Figure 24.1
Use 7/16 Socket Wrench
and Remove Channel Nuts
Figure 24.2
2 Baffle Boards
R
Baffle Protection
Channel
May 23, 2013