VOYAGEUR GRAND Wood Insert
F. 2-10-3 Rule
These are safety requirements and are not meant to assure proper flue draft.
This appliance is made with a 6 inch (152mm) diameter chimney connector as the flue collar on the unit.
Changing the diameter of the chimney can affect draft and cause poor performance.
It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when
there are other factors that affect flue draft.
3 ft. (91cm)
Minimum
Figure 28.1
Figure 28.2
Page 28
2 ft. (61cm)
10 ft. (305cm) To Nearest Roofline
10 ft. (305cm) or more
Wall or Parapet
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)
Pitched Roof
3 ft. (91cm) Minimum
Flat Roof
7075-166C
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
May 23, 2013