Advertisement

Includes INTELLICODE
®
2 Remote Control. Safe-T-Beam
®
System must be installed to close door.
Homelink
®
and Car2U
®
compatible.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
WARNING: To reduce the risk of injury to persons or damage to property, use this opener only with a
one-piece or sectional residential door up to 7 ft in height. Extension kit is available for 8 ft. one-piece
or sectional residential doors.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
INSTALLER:
LEAVE THIS MANUAL WITH HOMEOWNER.
Genie, Genie logo, Intellicode, Safe-T-Beam & PowerMax are registered trademarks of GMI Holdings, Inc., dba The Genie Company.
Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation. © The Genie Company 2011 PN# 37324500118, 4/2011

Advertisement

Table of Contents
loading

Summary of Contents for Genie POWERMAX 1200 3062

  • Page 1 Genie, Genie logo, Intellicode, Safe-T-Beam & PowerMax are registered trademarks of GMI Holdings, Inc., dba The Genie Company. Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation. © The Genie Company 2011 PN# 37324500118, 4/2011...
  • Page 2: Safety Information

    Could result in Death or Serious Installations, repairs and adjustments must be done by Injury a trained door system technician using proper tools and instructions. ©2011 The Genie Company 3/2011...
  • Page 3: Opener Features & Safety Features

    (Not available on all models) Select units have motion detection built into the powerhead. Lights automatically turn ON when motion is detected for much safer movement through the garage. Lights will turn OFF after 4 minutes of no motion. ©2011 The Genie Company 3/2011...
  • Page 4: Table Of Contents

    Troubleshooting Guide - Operation ............. 24-25 Troubleshooting Guide - Powerhead LEDs ..........25 Reference - Wiring Diagram ................26 Warranty ........................27 OPENER MUST BE INSTALLED WITH THE INCLUDED Safe-T-Beam® SAFETY REVERSE SYSTEM MUST BE WALL CONSOLE. INSTALLED TO CLOSE DOOR. ©2011 The Genie Company 3/2011...
  • Page 5: Important Installation Instructions

    There are no assembly or installation steps included in this manual. Contact your Genie® Professional Dealer for an installation poster, if required, or visit www.geniecompany.com to download a PDF file. The following mechanical assembly tasks must be completed before continuing.
  • Page 6: Programming Limits & Force

    ©2011 The Genie Company 3/2011...
  • Page 7: Open Door Travel Limit

    ©2011 The Genie Company 3/2011...
  • Page 8: Contact Reverse Test

    ©2011 The Genie Company 3/2011...
  • Page 9: Program Intellicode® 2 Remote To Powerhead

    ©2011 The Genie Company 3/2011...
  • Page 10: Programming Homelink®, Car2U®, Intellicode® 1 Remotes Or Wireless Keypads

    ©2011 The Genie Company 3/2011...
  • Page 11: Typical Installed Illustrations

    REMARQUE: Utilisez la console sur le mur et les capteurs de sécurité fournis avec cet appareil. NE PAS substituer la console du mur ou les capteurs de sécurité. NOTA: Use la consola de pared y los sensores de seguridad proporcionados con esta unidad. NO sustituya la consola de pared ni los sensores de seguridad. ©2011 The Genie Company 3/2011...
  • Page 12: Typical Sectional Door Installation

    .........POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE UNA PUERTA SECCIONAL ......... PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must reach grounded outlet without use of extension cord.
  • Page 13: Typical One Piece Door Installation

    .....POUR OBTENIR DE L’AIDE-1-800-35-GENIE INSTALACIÓN HABITUAL DE PUERTA DE UNA SOLA PIEZA ........PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE *If required direct wiring of power supply to opener must be installed by a licensed electrician. Power cord must reach grounded outlet without use of extension cord.
  • Page 14: Overview Of Powerhead Controls

    30 seconds if there is no key stroke through menus activity. Open Travel button multi-function; moves door, advances through menus LED Colors Round Red Long Red Round Purple Long Purple Round Blue Long Blue ©2011 The Genie Company 3/2011...
  • Page 15: Overview Of Remotes And Options

    Re-orient or relocate the receiver antenna. Increase the separation between the opener and receiver. Connect the opener into an outlet on a circuit different from that to which the receiver is connected. Consult your local dealer. ©2011 The Genie Company 3/2011...
  • Page 16: Intellicode® Features

    IntelliCode® 2 openers One or more openers Use IntelliCode® manufactured between 1997 5. Take the remote to the older Genie® garage door and 2010 (IntelliCode® 1) opener and follow that opener's instructions to program a new remote. NOTE: A maximum of 3 different openers can be programmed to a 3 button remote.
  • Page 17: Maintenance & Troubleshooting

    Bestimmungen der USA und Kanadas abweichen. MAINTENANCE & TROUBLESHOOTING FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM If you have any questions, please do not hesitate to contact customer service at: 1-800-35-GENIE IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of severe injury or death: 1.
  • Page 18: Routine Monthly Maintenance

    – Stops before it contacts the 2 x 4 board, it may simply be responding to an improperly set down limit. Return to pages 6-7 and repeat steps 1 through 10 to correct down limit. FIG. 6-2 2 x 4 under center of door opening ©2011 he Genie ompany...
  • Page 19: Change Light Bulbs

    RESET - OPEN/CLOSE TRAVEL LIMIT Performing all ten (10) Limits/Force setting steps (pages 6-7) erases previous Limits/Force settings. NOTE: The opener will not close the door automatically unless the Safe-T-Beam® System is installed and Limits are programmed. ©2011 The Genie ompany 3/2011...
  • Page 20: Wall Console - Overview

    Indicator Light Use the wall console supplied with this opener. Other Red indicator light is always ON Genie® wall consoles may be available for upgrade. Confirm compatibility prior to installing as some wall consoles may When Sure-Lock™ is ON the not operate this opener properly.
  • Page 21: Remote Battery Replacement

    Replace remote battery with a CR 2032 coin cell battery. 1. Open the remote case using a washer or coin that fits into the slot at the top of the remote. 2. Replace battery. 3. Align components and snap case closed. ©2011 The Genie Company 3/2011...
  • Page 22: Speed Adjustment Guide

    ADJUSTMENT GUIDE - SPEED SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM Speed settings are pre-programmed at the factory CHANGE SPEED SETTING for the maximum speed. Speed settings should not Use this guide to ADJUST powerhead SPEED settings. need adjustment with this unit.
  • Page 23: Force Adjustment Guide

    ADJUSTMENT GUIDE - FORCE SETTINGS FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM CHANGE FORCE SETTING CAUTION Use this guide to ADJUST powerhead FORCE settings. Door closing force is FACTORY set and requires no NOTE: There are nine (9) force levels. adjustment for normal operation.
  • Page 24: Troubleshooting Guide - Operation

    TROUBLESHOOTING GUIDE - OPERATION FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM PROBLEM WHAT TO DO rce, work , ow r ker. Opener does NOT run from wall console. re-L re-L , rok re . re . Opener runs, but door does NOT move.
  • Page 25: Troubleshooting Guide - Powerhead Leds

    TROUBLESHOOTING GUIDE - OPERATION (CONTINUED) ..............FOR HELP-1-800-35-GENIE PROBLEM WHAT TO DO Noisy operation. r, r Door opener runs slow. eet, TROUBLESHOOTING GUIDE - POWERHEAD LEDs FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM Powerhead LED Possible Problem Solution Round LED Long LED ter eren e...
  • Page 26: Reference - Wiring Diagram

    ............POUR OBTENIR DE L’AIDE-1-800-35-GENIE REFERENCIA - ESQUEMA ELÉCTRICO DEL CIRCUITO ............PARA OBTENER AYUDA, LLAME AL 1-800-35-GENIE Opener circuit wiring diagram. This wiring diagram is for reference only. Schéma de câblage de l’ouvreur. Ce schéma de câblage est indiqué à titre de référence uniquement.
  • Page 27: Warranty

    This page left blank.
  • Page 28 G900-924...

This manual is also suitable for:

Powermax 12003062

Table of Contents