D. Junction Box Installation
If the box is being wired from the OUTSIDE of
the appliance:
• Remove the cover plate located on the outer
shell - right side (see Figure 10.3).
• Install the supplied Romex™ connector in the
cover plate.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections and
reattach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box/
receptacle to the outer shell, rotate the junction
box inward to disengage it from the outer shell
(see Figure 10.3).
• Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
Figure 10.3 Junction Box Detail
• Feed the necessary length of wire through the connector.
• Make all necessary wire connections to the junction box/receptacle
and reassemble the junction box/receptacle to the outer shell.
Heat & Glo • Escape-36DV • 2012-900 • Rev. AB • 10/08
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
GRN wire
to GRN screw with
inside box
GRN wire
Note: Do NOT wire
110VAC to wall switch.