Super-Magnum Coal Stoker Stove
10
Service & Maintenance
A. Shut-down Procedure
The best way to shut down the appliance is to simply let it
run out of fuel, and shut down naturally as the temperature
cools. This method is highly recommended for the end of
season shut-down.
To shut-down otherwise, turn the mode selector to "OFF'
verify by ensuring that the Status light goes out. The shut-
down protocol of the circuit board will safely allow the fire
to go out.
B. Quick Reference Maintenance Chart
Cleaning or Inspection
Area beneath fire grates
Ash removal
Combustion blower
Distribution air filter
Distribution blower
Door latch inspection
Fines tray
Firebox / thorough cleaning
Glass
Heat exchanger / Chain scraper
Hopper
Venting system
24
Do Not Burn Wet Coal!
Soot Formation and Need For Removal- When coal is
burned, the products of combustion combine with moisture
to form a soot residue which accumulates on the flue lining.
When ignited, this soot makes an extremely hot fire. The
chimney and chimney connector should be inspected at
least once every two months during the heating season
to determine if a soot buildup has occurred. If soot has
accumulated, it should be removed to reduce the risk of a
chimney fire.
If you experiance a chimney fire; Remove all burning fuel
from the grate by scraping it into the ash pan. Move the ash
pan safely outside the home and place it on the ground,
well away from any combustibles. Turn the control to "Off"
and notify the fire department. Do not operate the appliance
until the chimney and connector have been inspected and
approved by a chimney professional.
Frequency
After each ton burned
Whenever filling the unit hopper
More frequently depending on
surroundings
Replace as needed
More frequently depending on
surroundings
Prior to heating season
Depending on fuel quality
End of heating season
When veiw of fire becomes
obstructed
Whenever filling the unit hopper
Whenever adding fuel
More frequently depending on fuel
quality and quantity
Daily Weekly Monthly Yearly
OR
OR
X
OR
OR
OR
OR
OR
X
OR
X
OR
OR
X
OR
OR
X
X
X
X
X
X
X
X