INSTALLER: Leave this manual with party responsible for use and operation.
OwNER: Retain this manual for future reference.
NOTICE: SAVE THESE INSTRUCTIONS
Model(s):
P43, P61A & P68
Freestanding Pellet Stove
!
Tested and approved for wood pellets and shelled field
corn fuel only. Burning of any other type of fuel voids
your warranty.
!
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
1
Installation Manual
Installation and Appliance Setup
CAUTION
CAUTION
Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not overfire - If any external part starts to glow, you
are overfiring. Reduce feed rate. Overfiring will void
your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
wARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
stove.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other
flammable materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
NOTE
To obtain a French translation of this manual, please
contact your dealer or visit www.harmanstoves.com
Pour obtenir une traduction française de ce manuel, s'il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
wARNING
3-90-436168i

Advertisement

Table of Contents
loading

Summary of Contents for Harman P43

  • Page 1 To obtain a French translation of this manual, please Check building codes prior to installation. contact your dealer or visit www.harmanstoves.com • Installation MUST comply with local, regional, state and national codes and regulations. Pour obtenir une traduction française de ce manuel, s’il • Contact local building or fire officials about restrictions and vous plaît contacter votre revendeur ou visitez www. installation inspection requirements in your area. harmanstoves.com Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 2: Table Of Contents

    I. Fire Safety ........20 J. Inspect Appliance & Components ....20 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 3: Installation Standard Work Checklist

    Electrical Section 1 (Pg. 5) 120VAC unswitched power provided to the appliance. ________________________________ Appliance Setup Section 5 (Pg. 21-22) All packaging and protective materials are removed ________________________________ Accessories installed properly ________________________________ Manual bag and all it’s contents are removed from inside the appliance and given to party responsible for use and operation ________________________________ Started appliance and verified that all motors and blowers operate as they should. ________________________________ Hearth and Home Technologies recommends the following: Photographing the installation and copying this checklist for your file. This checklist remain visible at all times on the appliance until the installation is complete. Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed __________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments communicated to party responsible____________________ by ________________________ on __________ (Builder / Gen Contractor) (Installer) (Date) Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 4: Product Specific And Important Safety Information

    In the absence of local codes you must comply with the ASTM E1509-2004, ULC S628-93, ULC/ORD-C- 1482-M1990, (UM) 84-HUD The P61A and P68 Freestanding Pellet Stove by Harman® are exempt from Environmental Protection Agency certification under 40 CFR 60.531 by definition [Wood Heater (A) “Air to Fuel Ratio]. The P43 is EPA certified to comply with July 1990 particulate  emission standards. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 5: Btu Specifications

    290 lbs • Install parts or components not Listed or approved. *BTU output will vary, depending on the brand of fuel you use in • Disable safety switches your appliance. Consult your Harman® dealer for best results. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your dealer. NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice. Harman is a registered trademark of Hearth & Home Tech- ® nologies. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 6: Getting Started

    • Lower roof line • Avoid outside wall in cooler climates Windward Leeward Multi-level Roofs Recommended: NOT recommended: Outside Air Intake Outside Air Intake on windward side on leeward side Figure 2.1 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 7: Tools And Supplies Needed

    Call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 8: Appliance Dimension Diagram

    P43 Freestanding Pellet Stove P61A Freestanding Pellet Stove Outside Outside Air Intake Air Intake 5 1/8" 5 1/8" 22" 23 1/2" 20 3/4" P68 Freestanding Pellet Stove Outside Air Intake 5 1/4" 23-1/2” Figure 3.1 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 9: Clearances To Combustibles

    P61A & P68 Freestanding Pellet Stove P43 Freestanding Pellet Stove 2"(51mm) 2"(51mm) 14" (355mm) with *10" (254mm) with side shields side shields 20" (508mm) *16" (406mm) without side shields without side shields *10" (254mm) 14" (355mm) *16" (406mm) 20" (508mm) 36"(914mm) 36"(914mm) 9"(228mm) 9"(228mm)- 13"(330mm) 9"(228mm)With Side Shields 9" (228mm) With or Without Side Shields 13"(330mm) Without Side Shields Figure 3.2 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 10: Floor Protection

    Corner to edge dimension for corner installation floor protection. Canada Requirements Sides 6" 200mm Front 6" 450mm Rear 6" 200mm P43 = 42-5/8” NOTE: Measurement "L" is measured from P61A/P68 = 50” the pedestal base in the US ONLY NOTE: Measurement “K” is measured from the glass in the US ONLY CANADA loor protector Figure 3.3 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 11: Termination Location And Vent Information

    Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building. 3 Ft. to Combustibles Figure 4.2 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 12 Kaowool, mineral wool or an equivalent non- combustible insulation is recommended to be installed on top of the sealing plate to reduce the possibility of condensation. The connector pipe should extend through the smoke chamber to the base or into the first flue tile. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. Be sure to design the venting so that it can be easily cleaned. Figure 4.4 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 13 #6 Installing into an existing chimney (Figure 4.6) w/Full liner This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. The pipe or liner inside the chimney should be 4" diameter. In this method a cap should also be installed on the chimney to keep out rain. Figure 4.6 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 14 Through the ceiling vent, follow PL vent manufacturers clearance to combustible materials such as shrubbery, recommendations when using wall and ceiling pass through. mulch or tall grasses. Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer. Note: Do not place joints within wall pass-through. min. wall to outlet 12" Figure 4.9 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 15: Chimney Diagram

    NOTE: where passage through a wall, or partition of pipe. combustible construction is desired, the installation G. The clearance to an inside corner is 12". shall conform to CAN/CSA-B365. (if in Canada) H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 16: Venting & Use Of Elbows

    4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built wood burning fireplaces with class A metal chimneys. All pellet vent pipe must be secured together either by means provided by pipe manufacturer or by 3 screws at each joint. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 17: Outside Air

    House demand may consume some air needed for the stove, especially during a power failure. It Figure 4.12 may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house. To install outside air use 3". non-combustible flex pipe Figure 4.13. There is a break-away hole on the rear panel of the Termination Cap P-Series stove which must be removed before connecting part# 1-10-09542 the flex pipe. Figure 4.12. The pipe should be run outside and terminate to the side or below the vent pipe outlet so the flue outlet is more than 12" from the inlet cover. The Termination Cap should be used to keep birds, rodents, etc. out of the pipe Figure 4.13. Figure 4.13 You may choose to use the optional Direct Vent Wall Pass- through Kit which incorporates the venting pass-through and Direct Vent Wall Pass-through Kit outside air inlet into one component. Figure 4.14. (Part #1-00-677177) Figure 4.14 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 18: Locating Your Appliance And Chimney

    Minimum Vacuum Requirements: .35 - .55 • Inadequate draft due to environmental conditions Prior to installing the flue pipe, connect a draft meter. (The • Downdrafts draft meter must have a minimum range of 0 - .5”) Record the • Tight sealing construction of the structure first reading. Connect flue pipe to stove and be sure all doors • Mechanical exhausting devices and windows in the home are closed. Record the second draft reading _______. If the second reading is more than .05” lower than the first reading, check for possible restrictions or the need for outside air. For more information on the draft test procedure, refer to Page 21 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 19: Avoiding Smoke & Odors

    House demand may consume the air needed for the appliance. It may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house. Vent Pipe Be sure to use approved pellet vent pipe wall and ceiling pass- through fittings to go through combustible walls and ceilings. Be sure to use a starting collar to attach the venting system to the stove. The starting collar must be secured to the flue stub with at least three screws, and sealed with high temp silicone caulking. 4" stainless steel flex vent piping is only allowed for use in masonry fireplaces and chimneys or factory built wood burning fireplaces with class A metal chimneys. Pellet venting pipe (also known as Type L vent) is constructed of two layers with air space between the layers. This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 1 inch. The sections of pipe lock together to form an air tight seal in most cases; however, in some cases a perfect seal is not achieved. For this reason and the fact that the P-Series operates with a positive vent pressure, we specify that the joints also be sealed with silicone. Where passing through an exterior wall or roof, be sure to use the appropriate pass-through device providing an adequate vapor barrier. Venting manufacturers generally provide these pass-through devices. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 20: Fire Safety

    • Installation other than as instructed by Hearth & Home Technologies. • Installation and/or use of any component part not approved by Hearth & Home Technologies. • Operating appliance without fully assembling all components. • Do NOT Overfire. Or any such action that may cause a fire hazard. Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 21: Appliance Setup

    If needed, install the (2) 5/16-18 X 3/4” leveling bolts located in the hardware kit. Figure 5.1. Leveling Bolt C. Firebrick Leveling Bolt Shipping Bolts The P43 Pellet Stove has a single (1) firebrick that gets Note: These same holes are used for securing the stove in mobile home installed horizontally on the angle bracket above the burnpot. Figure 5.1 installation. The P61A and P68 have three (3) firebrick that get installed vertically on the angle bracket. Figure 5.2. D. Flame Guide Install the cast iron flame guide on top of the burn pot. Make...
  • Page 22: Room Sensor

    Figure 5.5 Connect the power cord to a 100 VAC, 50 Hz grounded receptacle. (A surge protector is recommended to protect the circuit board.) Also be sure that the polarity of the outlet that the stove is plugged into is correct. Figure 5.4 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 23: Reference Materials

    USE OF IMPROPER FUELS, FIRE STARTERS OR ALTERING THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE. USE ONLY APPROVED FUELS AND OPERATION GUIDELINES Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 24: Wiring Diagram

    B. wiring Diagram Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 25 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...
  • Page 26 Harman , a brand of Hearth & Home Technologies Inc. ® 352 Mountain House Road, Halifax, PA 17032 www.harmanstoves.com Please contact your Harman dealer with any questions or concerns. ® For the location of your nearest Harman dealer, ® please visit www.harmanstoves.com. Printed in U.S.A. - Copyright 2012 Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/14 3-90-436168i...

This manual is also suitable for:

P61aP68

Table of Contents