Download Print this page
Harman SF 250 Installation And Operating Manual

Harman SF 250 Installation And Operating Manual

Coal stove
Hide thumbs Also See for SF 250:

Advertisement

Installation & Operating manual
The harman SF 250 Coal Stove
r3

SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr. FAIlurE
TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.
FOr uSE IN ThE u.S. ANd CANAdA. NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES
IF ThIS hArmAN STOvE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT. FOr YOur SAFETY, FOl-
lOw INSTAllATION dIrECTIONS.
CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION
rEQuIrEmENTS IN YOur ArEA.
CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE
PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.
CETTE guIdE d'uTIlISATION EST dISPONIblE EN FrANCAIS. ChEz vOTrE CONCESSIONNAIrE dE hArmAN
hOmE hEATINg.
R1
SAvE ThESE INSTruCTIONS.

Part # 3-90-70738

Advertisement

loading

Summary of Contents for Harman SF 250

  • Page 1: Safety Notice

    TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh. FOr uSE IN ThE u.S. ANd CANAdA. NOT SuITAblE FOr INSTAllATION IN mObIlE hOmES IF ThIS hArmAN STOvE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT. FOr YOur SAFETY, FOl- lOw INSTAllATION dIrECTIONS.
  • Page 2: Table Of Contents

    TAblE OF CONTENTS Safety Considerations...3 Assembly...4 Installation...5 Chimney & Venting...6 Operating Instructions...8 Preventive Maintenance...9 Optional Hot Water Coil...0 Testing Label... Warranty...3...
  • Page 3: Safety Considerations

    During the first few hours of burning, a blue smoke will be observed rising from the painted surface of the stove. It is advisable to increase the amount of fresh air (open window) in the room during this breaking-in period. Do not be alarmed, this is normal and does not cause harm.
  • Page 4: Assembly

    ASSEmblY blower The blower slides into the channel bracket on the rear of the stove as shown at right. Plug the blower into a properly grounded receptacle. Shaker handle The shaker handle installs onto the shaker handle mount using the two hex-bolts and washers provided.
  • Page 5: Installation

    Locate the stove as close to the chimney or flue as possible, while still maintaining the clearances to com- bustibles. Locate the stove where there is sufficient air supply for ventilation and proper combustion.
  • Page 6: Chimney & Venting

    IMPORTANT: When you measure the the draft, the stove must be operating with sufficient time given for the stove and chimney to warm. Burn for at least thirty minutes. The draft reading is best taken 18” up from the center of the flue outlet, in the connector pipe. Drill a hole in the pipe for the meter tube, and fill it with a screw or silicone when done with the test.
  • Page 7 9” round flue. In general for round liners, it is recommended that they not be increased by more than one inch from that of the stove collar. This will help ensure proper draft with the lower flue temperatures.
  • Page 8: Operating Instructions

    NEVER LEAVE THE STOVE UNATTENDED WITH A DOOR OPEN. Once you have a bed of burning coal, you can load coal into the stove to the top of the firebricks. Always make sure there is some flame showing through the coal. This will ensure the gases are being burned and not accumulating in the firebox.
  • Page 9: Preventive Maintenance

    The residue will fall down to the bot- tom of the chamber and can be removed through the flue opening on the back of the stove by means of a vacuum cleaner or a small scoop. mAINTENANCE...
  • Page 10 Place the coil through the holes in the stove, and adjust the nuts so that the pipes stick out about 1¼” to 1½” from the sidewall of the stove. Put flat wash- ers and nuts on the outside, and tighten within ¼...
  • Page 11 (2) at the high point of the line. The optional aquastat can be installed in this line a maximum of six feet from the stove. The aquastat must be a “close on temperature rise” type and must be wired and set to turn on the circulator when the water temperature reaches 120˚...
  • Page 12: Testing Label

    TESTINg lAbEl * This appliance is also approved for installation into a shop...