Clearances To Combustibles; Floor Protection - Harman Super-Magnum Owner's Manual

Coal stoker stove
Table of Contents

Advertisement

Super-Magnum Coal Stoker Stove
B. Clearances To Combustibles
A
Parallel
Installation
A
Back Wall To Unit Hopper
Side Wall To Unit
B
C
Back Wall To Flue Connector
D
Side Wall To Flue Connector
C. Floor Protection Requirements
54"
G
H
10
Do Not Burn Wet Coal!
C
D
B
Inches
Millimeters
2
24
17
34
J
G
Corner
Installation
E
51
Walls to Unit Body
610
Walls to Flue Connector
F
432
864
Floor protection must be of a non-combustible material. It
must be located under the appliance and extend beyond
the appliance according to the measurements below. Floor
protection must also extend under any horizontal sections
of chimney connector and 2" (50.8mm) beyond each side of
the connector.
DANGER: The appliance legs may not be removed for
installation.
Minimum Size floor protection is 49½" Deep By 42¾" Wide.

Floor Protection

Requirements
G
Sides- USA /CANADA *
H
Front- USA /CANADA *
J
Rear- USA
Alternate floor protector dimension may be used as long
as they satisfy the measurement requirements shown
above.
Minumum size floor protection for a corner installation
hearth pad is 54" x 54" (USA ONLY).
E
E
Inches
15
24
Inches
8
18
12
3-90-02702R6_03/13
F
Millimeters
381
610
Millimeters
203
457
305