Harman Super-Magnum Owner's Manual

Harman Super-Magnum Owner's Manual

Coal stoker stove

Advertisement

Owner's Manual

Installation and Operation

Model:
Super-Magnum
Coal Stoker Stove
Important operating and
maintenance instructions
included.
Please read this entire manual
before installation and use of this
coal-burning room heater.
Failure to follow these instructions
could result in property damage,
bodily injury or even death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
• Do not overfire - If any external part starts to glow,
you are overfiring. Reduce feed rate. Overfiring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specified. Failure to comply
may cause a house fire.
CAUTION
Tested and approved for use with anthracite "rice"
coal only. Burning any other type of fuel will void
your warranty.
3-90-02702R6_03/13
DO NOT DISCARD THIS MANUAL
Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
NOTICE
Leave this manual with
party responsible for use
and operation.
Hot, will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
WARNING
HOT SURFACES!
Glass and other surfaces
are hot during operation
AND cool down.
CAUTION
www.harmanstoves.com

Advertisement

Table of Contents
loading

Summary of Contents for Harman Super-Magnum

  • Page 1: Installation And Operation

    Owner's Manual Installation and Operation Model: Super-Magnum Coal Stoker Stove NOTICE DO NOT DISCARD THIS MANUAL • • • Important operating and Read, understand and Leave this manual with maintenance instructions follow these instructions party responsible for use included. for safe installation and and operation.
  • Page 2 The Super-Magnum has huge features in an elegant package, giving you 5000 to 100,000+ BTU when you need it, automatically. You need only set your desired room temperature, keep the hopper full, and the ash pan empty. With the Super- Magnum, you will notice even heat throughout your zone and a level of convenience you never thought possible.
  • Page 3: Table Of Contents

    Super-Magnum Coal Stoker Stove TABLE OF CONTENTS Section 1: Listing and Code Approvals Section 9: Troubleshooting A. Appliance Certifications Troubleshooting Chart B. Mobile Home Approval Section 10: Service & Maintenance C. Glass Specifications A. Shut-Down Procedure D. Electrical Rating B. Quick Reference Maintenance E.
  • Page 4: Section 1: Listing And Code Approvals

    Super-Magnum Coal Stoker Stove Listing and Code Approvals A. Appliance Certification E. BTU & Efficiency Specifications Model: Super Magnum Coal Stoker Particulate Emissions Not Tested Laboratory: OMNI-Test Laboratories, Inc. Rating: Report No. 135-S-24-6.2 *BTU Input: 5,000 - 103,000 / hr...
  • Page 5: Section 2: Special Warnings And Notes

    CO fumes are toxic and can be fatal. stove such as car or lawn mower exhaust. The Super-Magnum is a natural draft system which relies If the alarm sounds on a properly designed chimney to remove CO and other 1.
  • Page 6: Section 3: Getting Started

    Super-Magnum Coal Stoker Stove Getting Started A. Design, Installation & Location Considerations B. Fire Safety 1. Appliance Location Maintain the designated clearances to combustibles. Consideration must be given to safety, convenience, traffic Insulation must not touch the chimney. You must maintain flow, and the fact that the appliance will need a chimney and the designated air space around the chimney.
  • Page 7: Component Locator

    Super-Magnum Coal Stoker Stove C. Component Locations Coal Storage Hopper Removable Hopper Lid Heat Transfer Kit Filler Plate Air Grill Load Door Ash Removal Door Exhaust Sensing Probe (ESP) Heat Exchange Cleaning Rod Verti-Flow Feeder Control Panel Distribution Air Filter...
  • Page 8: Pre-Use Checklist

    Super-Magnum Coal Stoker Stove D. Pre- Use Check List Place the appliance in a location near the WARNING final installation and follow the procedures Inspect appliance components below: damage. Damaged parts may impair safe Open the appliance and remove all articles operation.
  • Page 9: Section 4: Dimensions & Clearances

    Super-Magnum Coal Stoker Stove Dimensions & Clearances A. Appliance Dimensions 3-90-02702R6_03/13 Do Not Burn Wet Coal!
  • Page 10: Clearances To Combustibles

    Super-Magnum Coal Stoker Stove B. Clearances To Combustibles Parallel Corner Inches Millimeters Inches Millimeters Installation Installation Back Wall To Unit Hopper Walls to Unit Body Side Wall To Unit Walls to Flue Connector Back Wall To Flue Connector Side Wall To Flue Connector Floor protection must be of a non-combustible material.
  • Page 11: Draft

    Super-Magnum Coal Stoker Stove Chimneys & Venting A. Draft No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through Draft is widely misunderstood. It is important that you, the a floor or ceiling.
  • Page 12: The Chimney

    Super-Magnum Coal Stoker Stove Closest Combustible Minimum 2" (50mm) Material Clearance to Brick Non-combustible cover, one side only. If two covers are Minimum 12" used, each must be mounted Hole with a minimum Liner (300mm) to Brick on non-combustible spacers clearance of 18"...
  • Page 13 Super-Magnum Coal Stoker Stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height, structural defects,...
  • Page 14: Draft Test Procedure

    Super-Magnum Coal Stoker Stove E. Draft Test Procedure Because of the dangers associated with coal gases and the potential for carbon monoxide release, It is important to balance the airflow into the stove with the draft in the flue. The combustion blower has a restrictor plate attached to it, which must be adjusted upon completion of the installation.
  • Page 15: Mobile Home Installation

    Super-Magnum Coal Stoker Stove Mobile Home A. Mobile Home Installation CAUTION Mobile home approval - U.S. only. 1. An outside air inlet must be provided for combustion Maintain structural integrity of mobile home: air, and must remain clear of leaves, debris, ice, and/or •...
  • Page 16: Section 7: Appliance Set-Up

    Super-Magnum Coal Stoker Stove Appliance Set-Up A. Outside Air Attachment Parts and Supplies Needed: 1 piece of metal flexible pipe, 3" X needed length. 1 Rodent Screen, Plus, you'll want to obtain a trim ring for finishing around the pipe on the inside wall.
  • Page 17: Leveling The Appliance

    Super-Magnum Coal Stoker Stove B. Leveling the Appliance D. Air Filter To adjust the leveling bolts, you must first loosen the locking To ensure cleanliness of the air circulated through the nut. Turn the leveling bolt to the desired position, and re heat exchange, the Super Magnum is equipped with a tighten the locking nut against the cast iron leg.
  • Page 18: Optional Door Trim Kit

    Super-Magnum Coal Stoker Stove F. Optional Door Trim Kit To Install the air grill, remove the existing painted grill. Then, using the same two screws and spring washers, The door trim kit includes a brushed stainless frame for install the brushed stainless grill.
  • Page 19: Section 8: Operating Instructions

    Super-Magnum Coal Stoker Stove Operating Instructions A. Fuel Specifications B. General Operating Information The Super Magnum is designed for use with Anthracite The Super Magnum's ESP control will maintain an output "Rice" coal Only. Anthracite is a hard coal which is mined level to fit your temperature demands.
  • Page 20: Circuit Board

    Super-Magnum Coal Stoker Stove 2. Circuit Board As stated previously, the circuit board is a microprocessor, which means it has the ability to "think" and adjust itself based on both reported temperatures and demand temperature. The circuit board also has the ability to self-diagnose when things are not happening as they should be.
  • Page 21 Super-Magnum Coal Stoker Stove a. Feed Rate Adjustment c. Temperature Dial The Circuit board runs on a one minute timer cycle. Each The temperature dial is a dual purpose dial. In Room-Temp minute, the board is thinking ahead to what it needs to do...
  • Page 22: Before Your First Fire

    Super-Magnum Coal Stoker Stove C. Before Your First Fire E. Fire Characteristics • Be sure the appliance is installed properly and that After lighting the fire, it will go through a few different stages all safety requirements have been met. Pay particular of appearance.
  • Page 23: Section 9: Troubleshooting

    Super-Magnum Coal Stoker Stove Troubleshooting With Proper installation, operation, and maintenance, your appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified person in the diagnosis of a problem and the corrective action to be taken.
  • Page 24: Shut-Down Procedure

    Super-Magnum Coal Stoker Stove Service & Maintenance A. Shut-down Procedure Soot Formation and Need For Removal- When coal is burned, the products of combustion combine with moisture The best way to shut down the appliance is to simply let it to form a soot residue which accumulates on the flue lining.
  • Page 25: General Maintenance Procedures

    Super-Magnum Coal Stoker Stove C. General Maintenance Procedures 2. Heat Exchanger Chain Scraper • Frequency: Daily 1. Ash Removal • By: User • Frequency: Daily Wear Gloves To Perform • By: User Whenever adding coal to the hopper, take the opportunity to Wear Leather Gloves To Prevent Skin Burns! clean the heat exchanger surfaces.
  • Page 26 Super-Magnum Coal Stoker Stove 3. Fines Tray Emptying 4. Door Glass • Frequency: Weekly • Frequency: As needed / Weekly • By: User • By: User Wear Gloves To Perform Whenever the view of the fire is obstructed, or weekly,...
  • Page 27 Super-Magnum Coal Stoker Stove 5. Air Filter 7. Firebox • Frequency: Monthly • Frequency: As necessary / Yearly • By: User • By: User Filter replacement is recommended every month. Follow Cleaning the firebox and internal heat exchange surfaces is the steps below to remove the filter.
  • Page 28: Motors And Components

    Super-Magnum Coal Stoker Stove 8. Chimney Connector • Locate the Allen-head set screw on the feed motor shaft and loosen it. • Frequency: As necessary / Yearly • Remove the 4 motor mounting screws and pull the motor • By: Qualified Service Technician / User out through the left, rear door.
  • Page 29 Super-Magnum Coal Stoker Stove 3. Distribution Blower 4. ESP- (Exhaust Sensing Probe) Requires no lubrication. Remove and wipe clean with a soft cloth and glass cleaner or alcohol. Change filter monthly to prevent build up of pet hair, etc. To remove the probe, you'll need to access the panel in the To remove distribution blower;...
  • Page 30: Section 11: Reference Materials

    Super-Magnum Coal Stoker Stove Reference Materials BLUE WHITE WHITE BLACK WHITE GREEN SUPPLY WHITE WHITE BROWN BLACK Do Not Burn Wet Coal! 3-90-02702R6_03/13...
  • Page 31: Service Parts Listing

    Super Mag Stoker Service Parts Beginning Manufacturing Date: July 2009 Coal Stove Ending Manufacturing Date: Active 1-90-02700-1 Part number list on following page. 03/13...
  • Page 32 Super Mag Stoker Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM Description...
  • Page 33 Super Mag Stoker Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM Description...
  • Page 34 Super Mag Stoker Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active #43 Feeder Assembly 43.8 43.3 43.7 43.4 43.2 43.5 43.6 43.1 43.9 43.14 43.10 43.13 43.7 43.11 43.12 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number.
  • Page 35 Super Mag Stoker Service Parts Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active #44 Motor Mount Assembly 44.4 44.3 44.5 44.6 44.7 44.2 44.10 44.1 44.8 44.9 4411 44.12 44.13 44.14 44.15 44.16 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number.
  • Page 36: Warranty Policy

    Hearth & Home Technologies LIMITED LIFETIME WARRANTY Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 37 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 38 Super-Magnum Coal Stoker Stove Service & Maintenance Log Date Of Service Performed By Description Of Service Do Not Burn Wet Coal! 3-90-02702R6_03/13...
  • Page 39 Super-Magnum Coal Stoker Stove Service & Maintenance Log Date Of Service Performed By Description Of Service 3-90-02702R6_03/13 Do Not Burn Wet Coal!
  • Page 40 At Harman, we build each product to a standard, not a price. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA. Proudly Printed On 100% Recycled Paper...