Error Messages; Procedure To Exit Ypao - Yamaha RX-V471 Owner's Manual

Av
Hide thumbs Also See for RX-V471:
Table of Contents

Advertisement

Optimizing
the speaker settings
automatically
(YPAO)
Error messages
If any error
message
is displayed
during
the measurement,
resolve
the problem
and perform
YPAO
again.
Error message
can
be confirmed
and controlled
by viewing
both
a TV
monitor
and the front display.
Procedure
to exit YPAO
TV monitor
Front display
2
3
4
Check the contents of error message, and then press ENTER.
Press the cursor key (i>) to select "EXIT (Exit)" from the following
choices, and then press ENTER.
Choices: PROCEED(Proceed) (E-5, E-9 only), "RETRY(Retry)," "EXIT(Exit)"
Press the cursor key (v) to select "Exit (Exit)" from the following
choices, and then press ENTER.
Choices: Start (Start), Exit (Exit)
Remove the YPAO microphone.
Cause and remedy for each error message
E-1 :No Front SP
Front speakers
are not
(E-1 :NO FRNT SP)
detected.
E-2:No Sur. SP
Either of surround
(E-2:NO SUR SP)
speakers
is not detected.
Follow "Procedure
to exit YPAO" to exit YPAO, turn off the unit, and then check the speaker connections.
After removing
problems,
turn on the unit, and
then perform
YPAO again.
Keep the room quiet and select "RETRY (Retry)" in step 2 of "Procedure
to exit YPAO" to restart YPAO for an accurate measurement.
Selecting
E-5:Noisy
The noise is too loud.
"PROCEED (Proceed)"
allows you to continue
measuring,
but may not achieve
the optimal results.
(E-5:NOISY)
We recommend
selecting
"RETRY (Retry)" or "EXIT (Exit)" to retry YPAO again from the beginning.
E-7:No MIC
The YPAO microphone
has
Connect
the YPAO microphone
to the YPAO MIC jack firmly and select "RETRY (Retry)" in step 2 of "Procedure to exit YPAO" to restart the measurement.
(E-7:NO MIC)
been removed.
E-8:No Signal
The YPAO microphone
Connect the YPAO microphone
to the YPAO MIC jack firmly and select "RETRY (Retry)" in step 2 of "Procedure
to exit YPAO" to restart the measurement.
(E-8:NO SIGNAL)
cannot detect test tones.
If this error occurs repeatedly,
contact
the nearest authorized
Yamaha dealer or service center.
E-9:User
Cancel
The measurement
has
Select "PROCEED (Proceed)"
in step 2 of "Procedure
to exit YPAO" to resume the measurement.
Select "RETRY (Retry)" to restart the measurement
from
(E-9:CANCEL)
been canceled,
first.
E-10:lnternal
Err.
An internal error has
Follow "Procedure
to exit YPAO" to exit YPAO, turn off and on the unit. Perform YPAO again. If this error occurs
repeatedly,
contact the nearest authorized
(E-10:INTERNAL)
occurred.
Yamaha dealer or service center.