Cmd27 (4Bh) - Set Baud Rate; Cmd28 (4Ch) - Download Baud Rate; Cmd29 (4Dh) - Set Operating Mode - Extron electronics Matrix 200 User Manual

Extron electronics user manual switch matrix 200
Hide thumbs Also See for Matrix 200:
Table of Contents

Advertisement

Appendix B • Programming Guide
CMD27 (4Bh) — Set Baud Rate
CMD28 (4Ch) — Download Baud Rate
CMD29 (4Dh) — Set Operating Mode
StsB1 is Status Byte #1,
described on page B-8, for
command CMD0.
_______ Vertical interval switching implies using the Genlock signal from the "Genlock
Extron • Matrix 200 • User's Manual
Sets the baud rate for the host controller. Front panel baud rate cannot be set
using this command. When the port is changing its own baud rate, this becomes
active only after the response has been sent back.
Format: CMD27, Port#, Rate, Cks1, Cks2, EOT
Where: Port# = 80h
81h
82-FFh reserved
Bits 3-0 of Rate byte encode the baud rate:
80h
81h
82h
83h
84h
85h
86h
87h
88-8Fh
Bits 6-4 = 0 for No Parity
Bits 6-4 = 1-7
Response: CMD27, Erc, Cks1, Cks2, EOT
The Host asks the Matrix 200 to send the baud rate of a specific port.
Format: CMD28, Port#, Cks1, Cks2, EOT
Response: CMD28, Erc, Rate, Cks1, Cks2, EOT
Where: Rate and Port# have the same format as in CMD27
The Host tells the Matrix 200 to enter a specific operating mode.
Format: CMD29, Mode, Cks1, Cks2, EOT
Where: Mode = 80h
enable vertical interval switching, set bit-3 of StsB1
81h
disable vertical interval switching, clear bit-3 of StsB1
82h
enter a slave mode, set bit-4 of StsB1
83h
enter an independent mode, clear bit-4 of StsB1
84h-FFh
reserved
Response: CMD29, Erc, Cks1, Cks2, EOT
In" connector on the back of the Matrix.
If vertical interval switching is enabled and there is no Genlock signal, switching
takes place after 50 ms.
host controller
n/a
300 baud
600 baud
1200 baud
2400 baud
4800 baud
9600 baud
19,200 baud
38,400 baud
reserved
reserved
B-18