_______ Using the View mode prevents changing configurations by accident.
Example #1: Configuring the Ties for Input 2.
Tie – A connection between an
Input and an Output.
Set of Ties – More than one
connection between one Input and
more than one Output.
Configuration – Any Tie, Set of
Ties, or Sets of Ties between
Input(s) and Output(s).
Active Configuration – The
configuration that is currently
being used by the Matrix 200.
Preset – A configuration that has
been stored.
_______ If an output had been tied to
Example #2: Display the Ties for Input 5.
4-23
Chapter 4 • Using the Front Panel Controller
View – Pressing the View button lights its LED for to indicate a "view-only" mode to
allow the display of the current Matrix 200 configurations. In this mode, pressing
any input or output button will also light all LEDs for the input and output(s) that
are part of that configuration. Pressing a button for any unassigned output will
light all of the unassigned outputs.
Page 4-24 has examples of Presets.
If necessary, press ESC to clear all Input,
Output and Control LEDs.
1. Select I/O modules to be switched.
(Example shows RGBS and Audio.)
2. Select the Input number. (Example
shows Input 2.)
3. Select the Output(s) to be tied to the
chosen Input. The Output LEDs will
blink to indicate the tentative
changes. (Example shows
Outputs 2 and 5.)
4. Press Enter to complete the
operation.
another input, that tie will be
broken in favor of the new one.
See picture, lower left.
If necessary, press ESC to clear Input,
Output and Control LEDs.
1. Select I/O modules to be switched (example shows RGBS).
2. Select the Input number (example shows Input 5).
The LED(s) for the Outputs (numbers 3, 4 and 7) will light to show
that they are connected to Input 5.
If an I/O module LED blinks when displaying ties, it means that the
ties for that module are not the same as those for the RGBS module.
3. Press ESC to clear all Input, Output and Control LEDs.