Installation and Operation, cont'd
If the events are currently stopped following the
momentary (<1 second) press, the Power LED will
flash twice indicating the starting of events.
or
If events are currently running following the
momentary (<1 second) press, the Power LED will
flash three times indicating the stopping of events.
Each flash will last for .25 seconds. Nothing happens if
the momentary press does not occur within 1 second.
Mode 4 — Holding the Reset button until the Power LED blinks
twice (6 seconds) followed by a momentary (<1 second)
press will reset IP settings. The Power LED will blink four
times in quick succession, confirming a Mode 4 reset. This
mode will
1. Enable ARP program capability.
2. Set IP back to factory IP.
3. Set Subnet back to factory default.
4. Set Gateway back to factory default.
5. Set port mapping back to factory default.
6. Turn DHCP off.
7. Turn events off.
Nothing happens if the momentary press does not occur
within one second.
Mode 5 — Holding the Reset button until the Power LED
blinks three times (9 seconds) followed by a momentary
(<1 second) press will cause an absolute system reset back
to factory default conditions. Nothing happens if the
momentary press does not occur within 1 second. The
power LED will blink four times in quick succession,
confirming a Mode 5 reset.
2-12
IPL T SF24 and IPL T SFI244 • Installation and Operation
IPL T SF24 and SFI244
Chapter Three
Connection and Configuration
3
Connecting the Hardware
Configuring the Hardware

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfi244 series

Table of Contents