CONNECTING
THE RETURN
AND SUPPLY
AIR FLEXIBLE DUCTS
a.
The supply duct for all units is 12" in diam-
eter. The return duct is 14" diameter for all
air conditioning
units.
b.
The flexible ducts can be connected to the
corresponding
fittings with the clamps pro-
vided with the ducts. Note: All connections
should
be leak tight or a loss in cooling
capacity will result.
c.
Theflexible ducts may be cut to the required
length, see instructions
packed with duct.
Keep all ducts as short and straight as pos-
sible. Avoid sharp bends.
d,
Ducts may be spliced with sheet metal
sleeves and clamps, (See Ducting Instal-
lation Accessories
page 6.)
e.
Once the inner duct is connected
to the
proper fitting, the insulation
and plastic
sleeve should be pulled over the connection
and clamped.
f.
For homes with multiple supply ducts or for
special applications, a Y fitting is available
to divide the supply air so it can be ducted
to different areas of the home for more ef-
ficient cooling. Note: The Y fitting should be
insulated for maximum performance.
Blower
Speed
--
For
optimum
system
performance
and comfort, it may be necessary
to change the factory set speed. See figure 7 for
factory settings. To change the blower speed:
High Efficiency Motor:
1,
Disconnect
all electrical
power to the unit
and remove the blower panel.
Model
Wire Color /
Motor
Air Flow
P5RF-
Speed Tap
Speed
1O.3 In.We !
TI
Low
520
Orange / T2
Med/Low*
560
X24K
Black / T3
Medium**
800
Red / T4
Med/Hiqh***
1040
T5
Hi,qh*
1250
Qranqe / T1
Low*
630
T2
Med/Low
988
X36K
Black / T3
Medium**
1068
Red / T4
Med/High***
1428
T5
Hi,qh
1508
Qranqe / T1
Low*
988
T2
Med/Low
1230
X48K
Red / T3
Medium***
1488
Black / T4
Med/High**
1508
T5
High
1688
TI
Low
1068
Orange/T2
Med/Low*
1204
X68K
Red/T3
Medium***
1504
Black/T4
Med/Hi,qh**
1788
T5
Hi,qh
1968
*
Denotes
Factory
Set Low Speed
Cooling.
** Denotes
Factory
Set High Speed
Cooling.
*** Denotes
Factory
Set Electric
Heating
Speed.
Figure 7,
8
_
P-Trap
Figure 8, Drain Trap
2.
Locate the orange, red and black wires ter-
minated to the blower motor.
The orange
wire controls
cooling operation,
red wire
controls
heating operation,
black controls
high speed cooling.
3.
Verify the required speed from the airflow
data found in figure 7. Place appropriate
wire on the appropriate motor speed tap for
the required airflow point.
Outdoor Motor: 4 and 5 Ton Models Only
The outdoor motor has variable speeds which
adjust in conjunction
with the compressor
and
indoor blower motor. The outdoor motor is pre-
set from the factory and is wired as follows. 4
Ton Model: The white wire is connected to Y1,
and the yellow wire is connected
to Y2. 5 Ton
Model: The yellow wire is connected to Y1, and
the white wire is connected to Y2. The blue wire
from the outdoor ECM motor is always common
for either speed setting.
Check all factory
wiring
per the unit wiring
diagram and inspect the factory wiring connec-
tions to be sure none loosened during shipping
or installation.
CAUTION:
To avoid personal injury or property
damage, make certain that the motor
leads cannot come into contact with
any uninsulated
metal components
of the unit.
CONDENSATE
DRAIN
A 3/4" condensate fitting extends out of the side
ofthe unit.The drain trap, shipped inthe electrical
compartment,
must be installed to prevent water
from collecting inside the unit.Thread the elbow
provided with the unit into the drain connection
until hand tight. Install the trap into the fitting and
seal the joint. Make sure it is level. Route the
condensate from the trap to a suitable drain. Any
connecting tubing or hose must have the outlet
below the trap level for proper drainage.